DK40i Installation
Loop Limits
3-40
Strata DK I&M 6/00
Loop Limits
This section provides the maximum loop lengths for connection of telephones, lines, peripheral
equipment, and power supplies. The following information applies to only the Strata DK40i
system (see
). Diagrams that are applicable to all systems, including the DK40i, can be
found in
Chapter 10 – Universal Slot PCB Wiring
Table 3-10
Digital Telephone/DIU/DDSS Console/ADM/Loop Limits
Mode
DK40i KSU or
Battery Backup
1
1. Battery backup applies to instances when the system is being powered by batteries exclusively.
Maximum line length (24 AWG)
1 Pair
feet meters
2 Pair
2
feet meters
2. Digital telephones and other digital devices can operate at maximum lengths with two pair wiring or an external power source.
1 Pair plus
external power
3
3. Digital cable runs must
not
have the following:
Cable splits (single or double)
Cable bridges (of any length)
High resistance or faulty cable splices
DKT or Cordless base Ringing
(Volume Max)
DK40i KSU
1000
303
1000
303
1000 feet
303 meters
Battery Backup
675
204
DKT with DVSU (OCA)
DK40i KSU
1000
303
Battery Backup
495
150
DKT with HHEU or Carbon Handset
DK40i KSU
1000
303
Battery Backup
330
100
DKT with PDIU-DI/
PDIU-DI2/RPCI-DI
DK40i KSU
495
150
Battery Backup
165
50
675
200
PDIU-DS
DK40i KSU
1000
303
1000
303
Battery Backup
675
204
1000
303
DKT with HHEU and
RPCI-DI/PDIU-DI/PDIU-DI2
DK40i KSU
495
150
1000
303
Battery Backup
33
10
330
100
DDSS2060A
DK40i KSU
1000
303
1000
303
Battery Backup
500
151
DDCB
DK40i KSU
1000
303
Battery Backup
500
151
DKT with DVSU and HHEU
DK40i KSU
1000
303
Battery Backup
165
50
DKT with ADM
DK40i KSU
675
204
Battery Backup
165
50
Mode
DK40i KSU or
Battery Backup
4
4. Battery backup applies to instances when the system is being powered by batteries exclusively.
Maximum line length (24 AWG)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...