2.4 System Board Troubleshooting
2 Troubleshooting Procedures
TECRA A9(S5/P5/S200) Maintenance Manual (960-633)[CONFIDENTIAL]
2-17
Procedure 1
Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. The IRT tests each IC on the system board and initializes it.
If an error message is shown on the display, perform Check 1.
If there is no error message, go to Procedure 2.
If DOS or Windows is properly loaded, go to Procedure 3.
Check 1 If one of the following error messages appears on the screen, press
F1
as the
message instructs. These errors occur when the system configuration preserved in
the RTC memory (CMOS type memory) is not the same as the actual
configuration or when the data is lost.
If you press
F1
as the message instructs, returns all system settings to their default
values. Then the system reboots.
If error message (b) appears often when the power is turned on, replace the RTC
battery. If any other error message displays, perform Check 2.
(a) *** Bad HDD type ***
Check system. Then press [F1] key ......
(b) *** Bad RTC battery ***
Check system. Then press [F1] key ......
(c) *** Bad configuration ***
Check system. Then press [F1] key ......
(d) *** Bad memory size ***
Check system. Then press [F1] key ......
(e) *** Bad time function ***
Check system. Then press [F1] key ......
(f) *** Bad check sum (CMOS) ***
Check system. Then press [F1] key ......
(g) *** Bad check sum (ROM) ***
Check system. Then press [F1] key ......
Summary of Contents for Satellite Pro S200
Page 11: ...TECRA A9 S5 P5 S200 Maintenance Manual 960 633 CONFIDENTIAL xi ...
Page 12: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 13: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 46: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 47: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 120: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 121: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 3 ...
Page 125: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 226: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 340: ... CONFIDENTIAL Appendices ...
Page 341: ...Appendices App ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...