3 Tests and Diagnostics
3.20 ONLY ONE TEST
3-44
[CONFIDENTIAL]
TECRA A9(S5/P5/S200) Maintenance Manual (960-633)
3.20.3 Subtest 3 Wireless communication switch
This subtest checks if the Wireless communication switch works properly.
If the test is started with the switch ON, following message appears in the
display.
Wireless communication switch is set to a start position (OFF)
Slide the switch to OFF position. Then, following message appears in the
display.
Wireless communication switch ON !!
Slide the switch to ON position. Then, following message appears in the
display.
Wireless communication switch OFF !!
After Sliding the switch to OFF position, return to the ONLY ONE TEST
menu automatically.
3.20.4 Subtest 4 USB Port Select menu
NOTE
: When executing this subtest, USB test module and USB cable must be connected.
This subtest checks if USB port works properly.
The following menu appears in the display.
################################################################
######## Port Select menu ######
################################################################
*
*
*
0 ............ Port 0 (right side front)
*
*
1 ............ Port 1 (right side back)
*
*
2 ............ Port 2 (Left side)
*
* 9
Exit
*
*
*
****************************************************************
.... Press test number[0-2, 9] ?
Connect the USB test module and USB cable to the computer.
Input the port test number and press
Enter
.
OK message appears in the display if the test ends without fail.
NG message appears in the display if an error is found during the test.
Confirm the connection of cable, and then execute the test again.
Press
9
and
Enter
to return to ONLY ONE TEST menu.
Summary of Contents for Satellite Pro S200
Page 11: ...TECRA A9 S5 P5 S200 Maintenance Manual 960 633 CONFIDENTIAL xi ...
Page 12: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 13: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 46: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 47: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 120: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 121: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 3 ...
Page 125: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...
Page 226: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 340: ... CONFIDENTIAL Appendices ...
Page 341: ...Appendices App ii CONFIDENTIAL TECRA A9 S5 P5 S200 Maintenance Manual 960 633 ...