430 Series
3-5
4.
Select the desired subtest number from the subtest menu and press
Enter
. The
following message will appear:
TEST LOOP
: YES
ERROR STOP : YES
Selecting
YES
for
TEST LOOP
sets the test to run continuously until it is halted
by the user. Selecting
NO
returns the screen to the main menu after the test is
complete.
Selecting
YES
for
ERROR STOP
stops the test program when an error is found
and displays the operation guide on the right side of the display screen as shown
below:
ERROR STATUS NAME [[ HALT OPERATION ]]
1: Test end
2: Continue
3: Retry
These three selections have the following functions, respectively:
1:
Terminates the test program and exits to the subtest menu.
2:
Continues the test.
3:
Restarts the test from the error.
Use the arrow keys to move the cursor to the desired option and press
Enter
.
Selecting
NO
for
ERROR STOP
keeps the test running even if an error is found.
Table 3-1 in Section 3.3 describes the function of each test on the subtest menu.
Table 3-2 in Section 3.17 describes the error codes and error statuses for each
error.