238
model 3000 DeviceNet Module Manual (DN311/DN311A)
Appendix E DN311A
E
(6) 7 segment LED display
B. "Local node parameter" is written in DN311A.
Using old model DN311, the user must set the local node parameter in DN311 by the
ladder program at each time of control power supply turning on (or module reset).
DN311A memorizes the local node parameter to the nonvolatile memory in oneself (as
well as the slave device parameter).
For this reason, if the local node parameter and the slave device parameter are set once
as DN311A, a user can make DN311A the run mode after a control power supply turning
on (or module reset) using the operation mode control request.
C. DN311A corresponds to DeviceNet Wizard for TOSHIBA.
C-1 Registration of local node parameter and slave device
parameter
The user needed to carry out the local node parameter setup and the slave device
parameter registration to old model DN311 by the ladder program.
DN311A can use DeviceNet Wizard for TOSHIBA (option), the user can register a self-
node parameter and a slave device parameter into DN311A using DeviceNet Wizard for
TOSHIBA.
The local node parameter registration and slave device parameter registration which
used the ladder program of course are also possible in DN311A.
C-2 Allocating slave device data to the input/output data area
in DN311A
In old model DN311, the slave device data is allocated from the head of input/output data
area for DN311 in order with small node address of the registered slave device (Refer to
4.4 Allocating Slave Device Data to the Input/Output Data Area).
In DN311A, after setting the slave device parameter in DN311A by using DeviceNet
Wizard for TOSHIBA, the user can freely allocate the slave device data to input/output
data area of DN311A.
Situation
Old model DN311
DN311A
The slave which does not exist
on a network was registered
into the master, and
transmission was started.
"72" and the node address of
the slave which does not exist
are displayed by turns.
"78" and the node address of
the slave which does not exist
are displayed by turns.
The response of a slave were
lost during normal transmission
between master and slave.
"72" and the node address of
the slave which does not exist
are displayed by turns.
"78" and the node address of
the slave which does not exist
are displayed by turns.
The receiving size of the slave
registered into the master
differed from the receiving size
of an actual slave.
"72" and the node address of
the slave from which reception
size is different are displayed
by turns.
"77" and the node address of
the slave from which reception
size is different are displayed
by turns.
The scan type of the slave
registered into the master
differed from the scan type of
an actual slave.
"72" and the node address of
the slave from which scan type
is different are displayed by
turns.
"83" and the node address of
the slave from which scan type
is different are displayed by
turns.