Auto Changeover

• During Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point 

temperature.

• If the Auto mode is uncomfortable, you can select the desired conditions manually.

Heating

• If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
• After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at 

extremely low speed.

 

During defrost operation, the fan stops so that cool air is not discharged. (“

” Pre-heat is displayed.)

When operation is restarted after stop

• When attempting to restart the unit immediately after it was stopped, the unit can not start for approx. 3 minutes this 

is to protect the compressor.

„

8°C operation (For object pre-heating)

 

 

(SDI series 4 and DI series 4 3 (RAV-SP***4AT / RAV-SM***4AT and ***3AT) only)

The air conditioner can control the heating temperature to about 8°C in the heating mode.

The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for 
the settings according to the installation manual of the indoor unit.

 

Start

Stop

NOTE

• The discharged air temperature is lower than that in the normal heating operation.
• The room temperature may not be heated evenly depending on the remote controller installation location.
• The room temperature may not reach 8°C depending on the room size or the installation conditions.
• Setting for fan speed is available during the 8°C heating operation.

The 8°C heating operation is cancelled in the following cases.
• When operation is stopped with 

 button

• When another operation mode is selected with 

 button

• When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote controller 

or the central control remote controller.

• When this operation mode is used, observe proper operating hours and we recommend that you ask service staff for 

periodic maintenance of the air conditioner.

1. Set the displayed temperature to 18°C in the heating mode by pushing TEMP. 

 button.

2. Set the displayed temperature to 8°C by pushing TEMP. 

 button for at least 4 seconds.

1. Set the displayed temperature to 18°C by pushing TEMP. 

 button.

• The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation 

mode.

5

Timer operation

Three timer modes are available: (Setting of up to 168 hours is enabled.)

Set

1

Push  

button.

The timer mode changes with every push of the 
button.

 and timer display flashes.

2

Push 

 to select “set time”.

• With every push of 

 button, the set time 

increases by 0.5 hr (30 minutes).

 

When a time more than 24 hours is set for timer 
operation, timer can be set in increments of 1 hr. 

 

The maximum set time is 168hr (7 days).

 

The remote control displays the set time with 
time (between 0.5 and 23.5 hours) (*

1

) or 

number of days and time (24 hours or more) (*

2

as shown below.

• With every push of 

 button, the set time 

decreases by 0.5 hr (30 minutes) (0.5 - 
23.5 hours) or 1 hr (24 - 168 hours).

Example of remote control display

23.5 hours (*

1

)

34 hours (*

2

)

3

Push  

button.

 display disappears and time display goes 

on, 

and  

or  

display 

flashes.

 

(When On timer is activated, time and On timer 

 are displays and other displays disappear.)

4

Cancel timer operation

Push  

button.

Timer display disappears.

NOTE

• When the operation stops after the timer reached the 

preset time, the Repeat Off timer resumes the 
operation by pushing 

 button and stops the 

operation after the time of the timer has reached the 
set time.

• When 

 is pushed while the Off timer function of 

the air conditioner is active, the indication of the timer 
function disappears and then appears again after 
about 5 seconds

.

 

This is due to normal processing of the remote 
controller.

Off timer

: The unit stops when the set time is reached.

Repeat Off timer

: The unit stops daily when the set time is reached.

On timer

: The unit starts when the set time is reached.

3


4

shows 1 day (24 hours).

shows 10 hours. (Total 34 hours)

(Off timer)

(On timer)

(Repeat Off timer)

No display

Off

Off

On

Number of days Time

13-EN

14-EN

+00EH99939501_01EN.book  Page 7  Thursday, January 12, 2012  4:31 PM

Summary of Contents for RAV-SM1106BT-E

Page 1: ... Indoor Unit Model name Concealed Duct Type RAV SM406BTP E RAV SM456BTP E RAV SM566BTP E RAV SM806BTP E RAV SM1106BTP E RAV SM1406BTP E RAV SM1606BT E English For commercial use P 00EH99939501_01EN book Page 1 Thursday January 12 2012 4 31 PM ...

Page 2: ...rson who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to work at heights has b...

Page 3: ...st this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If the...

Page 4: ...ing is completed Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer 1 or a qualified service person 1 Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To disconnect t...

Page 5: ...acking notice In case that cardboard boxes protrude out of pallet when stacking lay a 10 mm thick plywood over the pallet 5 cartons 2 Part names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Air discharge Connect a discharge duct Electrical control box The earth screw is provided in the electrical control box Drain pan Air inta...

Page 6: ...TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 8 6 16 4 2 3 5 7 13 15 14 1 9 12 11 10 7 Auto High Med Low 11 UNIT No display The selected indoor unit number is displayed Also number of indoor or outdoor unit which an error occurs is displayed 12 Central control display Displayed when the air conditioner is used under the cent...

Page 7: ...also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation When the circuit breaker is turned on the pa...

Page 8: ...you ask service staff for periodic maintenance of the air conditioner 1 Set the displayed temperature to 18 C in the heating mode by pushing TEMP button 2 Set the displayed temperature to 8 C by pushing TEMP button for at least 4 seconds 1 Set the displayed temperature to 18 C by pushing TEMP button The air conditioner returns to the normal HEAT mode Select a desired temperature and operation mode...

Page 9: ...the setting of power level Each push of the button changes the power level by 1 within the range from 100 to 50 The factory default is 75 4 3 1 5 2 UNIT No 1 1 UNIT No 1 2 UNIT No 1 3 UNIT No 1 4 Setting of power level in power saving mode 4 Push button 5 Push button to complete the setting NOTE When other electric appliances are used at the same time to avoid triggering the circuit breaker power ...

Page 10: ...he air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when an indoor unit is operated for 8 hours or more daily clean the indoor unit and outdoor unit at least once every 3 months Ask a professional for this cleanin...

Page 11: ... Discharged air smells unusual Various smells from the walls carpet clothes cigarette cosmetics or other things adhere to the air conditioner The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote controller are blinking Check again The room does not cool down or warm up Is the air intake or dis...

Page 12: ...bove conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 15 C to 15 C Wet bulb temp Roo...

Page 13: ...ow Generic Denomination Air Conditioner Model type RAV SM406BTP E RAV SM456BTP E RAV SM566BTP E RAV SM806BTP E RAV SM1106BTP E RAV SM1406BTP E RAV SM1606BTP E Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulations transposing into national law Declaration of incorporation...

Page 14: ...ss city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 144 9 Moo 5 Bangkadi Industrial Park Tivanon road Amphur Muang Pathumthani 12000 Thailand 00EH99939501_01EN book Page 109 Thursday January 12 2012 4 31 PM 1115460101 TOSHIBA CARRIER THAILAND CO LTD 144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...