background image

– 16 –

EN

ID

ID

TCF holder:

*

 

Under 70 dBA

3

2

*

*

9

2

*

*

7

3

*

*

37

*

*

12

Specifications

Model

Sound pressure level (dBA)

Weight (Kg)

Cooling

Heating

3

2

*

*

Declaration of Conformity

NOTE

This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s 
consent.

Manufacturer:

TOSHIBA CARRIER (THAILAND) CO., LTD.

144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi,
Amphur Muang, Pathumthani 12000, Thailand

TOSHIBA CARRIER EUROPE S.A.S
Route de Thil 01120 Montluel FRANCE

Hereby declares that the machinery described below:

Generic Denomination:

Air Conditioner

Model / type:

Commercial name:

Digital Inverter Series / Super Digital Inverter Series Air Conditioner

Complies with the provisions of the Machinery  Directive (Directive 2006/42/EC) and the regulations
transposing into national law

RAV-RM401CTP-E

RAV-RM561CTP-E

RAV-RM801CTP-E

RAV-RM1101CTP-E

RAV-RM1401CTP-E

RAV-RM401CTP-E
RAV-RM561CTP-E
RAV-RM801CTP-E
RAV-RM1101CTP-E
RAV-RM1401CTP-E

Product information of ecodesign requirements. (Regulation (EU) 2016/2281)

http://ecodesign.toshiba-airconditioning.eu/en

31-EN

32-EN

Summary of Contents for RAV-RM1101CTP-E

Page 1: ...or Unit Model name Ceiling Type Owner s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual For commercial use RAV RM401CTP E RAV RM561CTP E RAV RM801CTP E RAV RM1101CTP E RAV RM1401CTP E R32 or R410A ...

Page 2: ...educed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 3: ...n such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations and he or she is...

Page 4: ...tioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause the stack ...

Page 5: ...the indoor unit or service panel of the outdoor unit and do the work required Inside the air conditioner are high voltage areas and rotating parts Due to the danger of electric shocks or of your fingers or physical objects becoming trapped in the rotating parts do not remove service panel of the outdoor unit When work involving the removal of these parts is required contact a qualified installer 1...

Page 6: ...he unit has been refitted If there is a danger of the outdoor unit s toppling over do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified installer 1 or a qualified service person 1 to have the improvements or refitting done Do not set the circuit breaker to the ON position until the improvements or refitting is completed Do not customize the unit ...

Page 7: ...lammable sprays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire Stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Ask for cleaning of the air conditioner to be performed by the dealer Cleaning the air c...

Page 8: ...While this icon is flashing the model is being automatically confirmed Wait till icon has disappeared to use the remote controller SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 11 14 13 12 18 8 7 1 Operation mode The selected operation mode is displayed 2 Error display Displayed while the ...

Page 9: ...nt Select the desired set point by pushing TEMP or TEMP 2 button Timer set button Use to setup the timer 3 button Filter reset button Resets display after cleaning filter 4 button Test button Use only for service During normal operation do not use this button 5 button When the button is pushed the operation starts and it stops by pushing the button again When the operation has stopped the operatio...

Page 10: ...or cooling unit will start approximately 1 minute after mode is selected Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for approx 30 seconds When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed...

Page 11: ... On timer The unit starts when the set time is reached 1 3 2 4 Off timer On timer Repeat Off timer No display Off Off On shows 1 day 24 hours shows 10 hours Total 34 hours Number of days Time 6 Adjustment of wind direction For best cooling and heating performance adjust the louvers adjustment plates of up down wind direction appropriately Cold air descends and warm air rises so to heat a room tilt...

Page 12: ...ntrolled simultaneously Each time button left side of the button is pushed the display changes as follows Horizontal air flow adjustment To change the horizontal air flow direction point the vertical louvers inside the horizontal louver in your preferred direction NOTE When the horizontal louver is pointing downward in COOL mode water droplets may form on the surface of the cabinet or louver and d...

Page 13: ...For details contact the original retailer Setting of power level in power saving mode 8 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places Ask a qualified installer or qualified service person to do it Do not attempt it by yourself Cleaning air filters When the unit will not be used for a long time 1 Perform the fan operation for a ...

Page 14: ...Apply repair coating 9 Troubleshooting Check the points described below before requesting repair If you find something unusual even after checking the above stop running the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is dis...

Page 15: ...ower failure during operation will stop the unit completely To restart the operation push the ON OFF button on the remote controller Lightning or a wireless car telephone operating nearby may cause the unit to malfunction Turn off the main power switch or circuit breaker and then turn them on again Push the ON OFF button on the remote controller to restart Defrosting operation If the outdoor unit ...

Page 16: ...oily place or in a place where steam soot or corrosive gas is generated Do not install the air conditioner in a salty place such as seaside area Do not install the air conditioner in a place where a great deal of machine oil is used Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area Do not install the air conditioner in a place where su...

Page 17: ...ARRIER EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulations transposing into national law RAV RM401CTP E RAV RM561CTP E RA...

Page 18: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115653899 ...

Reviews: