Correct usage

When the air conditioner is used for the first time or when the setting is changed, follow the steps below. Settings 
are saved in memory and are displayed anytime the unit is turned on by pushing the 

 button.

Preparation

‡

When the circuit breaker is turned on, the partition lines are displayed on the remote controller.

* After the circuit breaker is turned on, the remote controller does not accept any commands for approx. 1 minute, 

this is not a failure.

REQUIREMENT

When the air conditioner is re-powered after it has not been used for a long period, turn on the circuit breaker at least 
12 hours before starting the air conditioner.

Start

1

Push

 

 

button.

The operation lamp illuminates, and the operation 
starts.

2

Select an operation mode with the “

” 

button.

One push of the button, and the display changes 
in the order shown below.

3

Select fan speed with “

” button.

One push of the button, and the display changes 
in the order shown below.

‡

When fan is in “

Auto”, fan speed is 

adjusted based on difference between set point 
and room temperature.

‡

In heating operation, if the room temperature is 
not heated sufficiently with speed “

Low” 

operation, select “

Med.” or “

High” 

operation.

‡

The temperature sensor detects the return air 
temperature at the indoor unit, which differs 
from the room temperature depending on the 
installation condition.
Set point is a target of room temperature.
(

 “Auto” is not selectable in the Fan 

mode.)

4

Select the set point temperature by pushing 
the “TEMP. 

” or “TEMP. 

” buttons.

Stop

Push

 

 

button.

The operation lamp goes off, and the operation stops.

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

4

Auto

Heat

Dry

Fan

Cool

(Dehumidify)

      Auto

High

Med.

Low

NOTE

Auto Changeover

‡

During Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point 
temperature.

‡

If the Auto mode is uncomfortable, you can select the desired conditions manually.

Cooling

If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.

Heating

‡

If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.

‡

After the heating operation has stopped, fan may continue to run for approx. 30 seconds.

‡

When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at 
extremely low speed.

‡

During defrost operation, the fan stops so that cool air is not discharged. (“

” Pre-heat is displayed.)

When the operation is attempted to restart after stop

When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes this 
is to protect the compressor.

8 °C operation (For object pre-heating)

 

The air conditioner can control the heating temperature to about 8 °C in the heating mode.

The 8 °C heating operation requires settings with the wired remote controller. Ask the installer or dealer 
for the settings according to the installation manual of the indoor unit.

Start

1. Set the displayed temperature to 18 °C in the heating mode by pushing TEMP. 

 button.

2. Set the displayed temperature to 8 °C by pushing TEMP. 

 button for at least four seconds.

Stop

1. Set the displayed temperature to 18 °C by pushing TEMP. 

 button.

‡

The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation mode.

NOTE

‡

The discharged air temperature is lower than that in the normal heating operation.

‡

The room temperature may not be heated evenly depending on the remote controller installation location.

‡

The room temperature may not reach 8 °C depending on the room size or the installation conditions.

‡

Setting for fan speed is available during the 8 °C heating operation.

‡

When this operation mode is used, observe proper operating hours and periodic maintenance by service staff is 
recommended.

The 8 °C heating operation is cancelled in the following cases.

‡

When operation is stopped with 

 button

‡

When another operation mode is selected with 

 button

‡

When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote 
controller or the central control remote controller.

17-EN

18-EN

Summary of Contents for RAV-RM1101CTP-E

Page 1: ...or Unit Model name Ceiling Type Owner s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual For commercial use RAV RM401CTP E RAV RM561CTP E RAV RM801CTP E RAV RM1101CTP E RAV RM1401CTP E R32 or R410A ...

Page 2: ...educed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 3: ...n such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations and he or she is...

Page 4: ...tioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause the stack ...

Page 5: ...the indoor unit or service panel of the outdoor unit and do the work required Inside the air conditioner are high voltage areas and rotating parts Due to the danger of electric shocks or of your fingers or physical objects becoming trapped in the rotating parts do not remove service panel of the outdoor unit When work involving the removal of these parts is required contact a qualified installer 1...

Page 6: ...he unit has been refitted If there is a danger of the outdoor unit s toppling over do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified installer 1 or a qualified service person 1 to have the improvements or refitting done Do not set the circuit breaker to the ON position until the improvements or refitting is completed Do not customize the unit ...

Page 7: ...lammable sprays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire Stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Ask for cleaning of the air conditioner to be performed by the dealer Cleaning the air c...

Page 8: ...While this icon is flashing the model is being automatically confirmed Wait till icon has disappeared to use the remote controller SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 11 14 13 12 18 8 7 1 Operation mode The selected operation mode is displayed 2 Error display Displayed while the ...

Page 9: ...nt Select the desired set point by pushing TEMP or TEMP 2 button Timer set button Use to setup the timer 3 button Filter reset button Resets display after cleaning filter 4 button Test button Use only for service During normal operation do not use this button 5 button When the button is pushed the operation starts and it stops by pushing the button again When the operation has stopped the operatio...

Page 10: ...or cooling unit will start approximately 1 minute after mode is selected Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for approx 30 seconds When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed...

Page 11: ... On timer The unit starts when the set time is reached 1 3 2 4 Off timer On timer Repeat Off timer No display Off Off On shows 1 day 24 hours shows 10 hours Total 34 hours Number of days Time 6 Adjustment of wind direction For best cooling and heating performance adjust the louvers adjustment plates of up down wind direction appropriately Cold air descends and warm air rises so to heat a room tilt...

Page 12: ...ntrolled simultaneously Each time button left side of the button is pushed the display changes as follows Horizontal air flow adjustment To change the horizontal air flow direction point the vertical louvers inside the horizontal louver in your preferred direction NOTE When the horizontal louver is pointing downward in COOL mode water droplets may form on the surface of the cabinet or louver and d...

Page 13: ...For details contact the original retailer Setting of power level in power saving mode 8 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places Ask a qualified installer or qualified service person to do it Do not attempt it by yourself Cleaning air filters When the unit will not be used for a long time 1 Perform the fan operation for a ...

Page 14: ...Apply repair coating 9 Troubleshooting Check the points described below before requesting repair If you find something unusual even after checking the above stop running the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is dis...

Page 15: ...ower failure during operation will stop the unit completely To restart the operation push the ON OFF button on the remote controller Lightning or a wireless car telephone operating nearby may cause the unit to malfunction Turn off the main power switch or circuit breaker and then turn them on again Push the ON OFF button on the remote controller to restart Defrosting operation If the outdoor unit ...

Page 16: ...oily place or in a place where steam soot or corrosive gas is generated Do not install the air conditioner in a salty place such as seaside area Do not install the air conditioner in a place where a great deal of machine oil is used Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area Do not install the air conditioner in a place where su...

Page 17: ...ARRIER EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulations transposing into national law RAV RM401CTP E RAV RM561CTP E RA...

Page 18: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115653899 ...

Reviews: