Toshiba RAV-HM1101UT-E Owner'S Manual Download Page 12

– 11 –

Check periodically

• If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water 

depending on the heat, humidity, or dust.

• In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where 

you purchased it.

NOTE

For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in 
use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended. 
Furthermore, regularly check the outdoor unit for rust and scratches, and remove them or apply rustproof treatment, if 
necessary.
As a general rule, when an indoor unit is operated for 8 hours or more daily, clean the indoor unit and outdoor unit at 
least once every 3 months. Ask a professional for this cleaning / maintenance work.
Such maintenance can extend the life of the product though it involves the owner’s expense.
Failure to clean the indoor and outdoor units regularly will result in poor performance, freezing, water leakage, and even 
compressor failure.

Maintenance List

Part

Unit

Check (visual / auditory)

Maintenance

Heat exchanger

Indoor / outdoor

Dust / dirt clogging, scratches

Wash the heat exchanger when it is clogged.

Fan motor

Indoor / outdoor

Sound

Take appropriate measures when abnormal sound 

is generated.

Filter

Indoor

Dust / dirt, breakage

• Wash the filter with water when it is contaminated.
• Replace it when it is damaged.

Fan

Indoor

• Vibration, balance
• Dust / dirt, appearance

• Replace the fan when vibration or balance is 

terrible.

• Brush or wash the fan when it is contaminated.

Air intake / discharge 

grilles

Indoor / outdoor

Dust / dirt, scratches

Fix or replace them when they are deformed or 

damaged.

Drain pan

Indoor

Dust / dirt clogging, drain 

contamination

Clean the drain pan and check the downward slope 

for smooth drainage.

Ceiling panel, 

louvers

Indoor

Dust / dirt, scratches

Wash them when they are contaminated or apply 

repair coating.

Exterior

Outdoor

• Rust, peeling of insulator
• Peeling / lift of coat

Apply repair coating.

8

Troubleshooting

Check the points described below before requesting repair.

If there is something unusual even after checking the above, stop running the unit, turn off the circuit breaker, and inform the 
dealer where you purchased the product of the product number and symptom. Do not attempt to repair the unit by yourself as 
doing so is dangerous. If the check indicator (

, etc.) is displayed on the remote controller LCD, inform the dealer 

of its content as well.

If any of the following occur, stop running the unit immediately, turn off the circuit breaker, and contact the dealer where you 
purchased the product.

• The switch does not work properly.
• The circuit breaker often blows out.
• You unintentionally put a foreign object or water inside.
• The unit cannot be run even after the cause of the protective device activation is removed.
• Other unusual conditions are found.

Symptom

Cause

It i

s not a ma

lfuncti

on.

Outdoor unit

• White, misty, cold air or water comes out

• Sometimes the noise of air leaking is heard.
• A noise is heard when the power is turned 

on.

• The fan of the outdoor unit is automatically stopped and 

defrosting is performed.

• The solenoid valve works when defrosting starts or stops.
• The outdoor unit is preparing for running.

Indoor unit

• Sometimes a swishing is heard.

• A clacking sound is heard.

• Discharged air smells unusual.

• Louvers close automatically during heating

• When the unit starts running, during operation, or 

immediately after the unit stops running, a sound such as 

water flowing may be heard, or the operation sound may 

become louder for a couple of minutes immediately after 

the unit starts running. This is the sound of the refrigerant 

flowing or the dehumidifier draining.

• This is a sound generated when the heat exchanger, etc. 

expands and contracts slightly due to temperature 

change.

• Various smells from the walls, carpet, clothes, cigarette, 

cosmetics, etc. adhere to the air conditioner.

In the following cases, the louvers close automatically to 

reduce the cold air falling from the indoor unit. 
• When defrosting during heating operation.
• Immediately after starting heating operation less than 12 

hours after turning on the circuit breaker when the outside 

temperature is low.

Check agai

n.

The unit does not run

• Has a blackout occurred?
• Has the circuit breaker blown?
• Has the protective device been activated? (The operation 

indicator and 

 on the remote controller are blinking.)

The room does not cool down or warm up.

• Is the air intake or discharge of the outdoor unit clogged?
• Is a door or window open?
• Is the air filter clogged with dust?
• Is the air volume set to “Low”? Or is the operation mode 

set to “Fan”?

• Is the setup temperature appropriate?

21-EN

22-EN

Summary of Contents for RAV-HM1101UT-E

Page 1: ...AIR CONDITIONER SPLIT TYPE Owner s Manual R32 Indoor Unit 4 way Cassette type RAV HM561UT E RAV HM801UT E RAV HM1101UT E RAV HM1401UT E Model name For commercial use English ...

Page 2: ...n individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she i...

Page 3: ...e to property indicates damage extending to buildings household effects domestic livestock and pets WARNING Risk of fire Read the OWNER S MANUAL carefully before operation Service personnel are required to carefully read the OWNER S MANUAL and INSTALLATION MANUAL before operation Further information is available in the OWNER S MANUAL INSTALLATION MANUAL and the like Warning indications on the air ...

Page 4: ...itioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position an...

Page 5: ...erwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of trouble such as when a check display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in the air conditioner do not touch the air conditioner yourself but set the circuit breaker to...

Page 6: ...rate it within the range of the operating temperature specified in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deterio...

Page 7: ...lity Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 8 8 cartons 2 Part names Indoor unit Hook Hook to open and close the air intake grille Air discharge discharge louver Change the direction of the wind blowing out when warming or cooling the room Ai...

Page 8: ...er If the use of the remote controller is prohibited by the central control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that t...

Page 9: ...is a demand for cooling unit will start approximately 1 minute after mode is selected When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for appr...

Page 10: ...n the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 Push the Menu button several times and select the wind direction mode to blink the wind direction 2 Push t...

Page 11: ...Information The following functions require a connection with the RBC AMTU and RBC AMSU remote controller For details consult the dealer where you purchased this product Individual unit selection during group operation Individual setting of louver position wind direction Swing type setting Louver lock no swing setting 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter ...

Page 12: ...ning the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit bre...

Page 13: ...g operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the fan of the indoor unit outdoor unit stops and the louver of the indoor unit closes During the defrosting operation the defrosted water will be drained from the bottom pl...

Page 14: ...g equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must not get wet Co...

Page 15: ...or Manager Quality Assurance Service Engineering Dept Date 07 April 2022 Place Issued Japan Declaration of Conformity NOTE This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Manufacturer TOSHIBA CARRIER CORPORATION 336 Tadehara Fuji shi Shizuoka ken 416 8521 JAPAN TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Indu...

Page 16: ...EH99970801 DH91308101 ...