background image

 

CAUTION

To disconnect the appliance from the mains supply.

• This appliance must be connected to the mains by means of a 

switch with a contact separation of at least 

3 mm

.

The installation fuse (all types can be used) must be used for 
the power supply line of this air conditioner.

Installation

• Certainly lay the drain hose for perfect draining. Improper 

drainage may cause 

fl

 ooding in the house and getting furniture 

wet.

• Connect the air conditioner to an exclusive power supply of the 

rated voltage, otherwise the unit may break down or cause a 

fi

 re.

• Con

fi

 rm that the outdoor unit are 

fi

 xed on the base. Otherwise, 

falling down of the units or other accidents may occur.

Operation

• Do not use this air conditioner for special purpose such as 

preserving food, precision instruments, art objects, breeding 
animals, car, vessel.

• Do not touch any switches with wet 

fi

 nger, otherwise you may 

get an electric shock.

• If the air conditioner will not be used for a considerably long 

time, turn off the main switch or the circuit breaker, for safety.

• To make the air conditioner operate in its original performance, 

operate it within the range of the operating temperature 
speci

fi

 ed in the instructions. Otherwise it may cause a 

malfunction, or water leak from the unit.

• Prevent any liquid from falling into the remote controller.

Do not spill juice, water or any kind of liquid.

• Do not wash the air conditioner. Doing so may result in electric 

shock.

• Check whether the installation base and other equipment have 

become deteriorated after being used for a long time. Leaving 
them such condition may result in the unit’s falling down and 
causing injury.

• Do not leave 

fl

 ammable sprays or other 

fl

 ammable materials 

near the air conditioner, and do not spray 

fl

 ammable aerosol 

directly to the air conditioner. They may catch 

fi

 re.

• Stop running the air conditioner and turn off the breaker before 

cleaning. Otherwise, injury may result as the fan is rotating at 
high speed inside the unit.

• Ask for cleaning of the air conditioner to be performed by the 

dealer.
Cleaning the air conditioner in an improper manner may cause 
damage to plastic parts, insulation failure of electric parts or 
other parts, and result in a malfunction. In the worst case, it may 
result in water leakage, electric shock, smoke emission or 

fi

 re.

• Do not put a water container such as a vase on the unit.

Water intrusion into the unit may occur and it may cause 
deterioration of electric insulation and result in electric shock.

(*1) Refer to the “De

fi

nition of Quali

fi

ed Installer or Quali

fi

ed 

Service Person.”

– 6 –

12-EN

11-EN

OM_1116950248_EN.indd   6

OM_1116950248_EN.indd   6

22/6/2564 BE   16:14

22/6/2564 BE   16:14

Summary of Contents for RAV-GM1101BTP-A

Page 1: ...Indoor Unit Model name For commercial use English Concealed Duct Type RAV GM561BTP A RAV GM801BTP A RAV GM1101BTP A RAV GM1401BTP A RAV GM1601BTP A 1116950248 OM_1116950248_EN indd 1 OM_1116950248_EN indd 1 22 6 2564 BE 16 14 22 6 2564 BE 16 14 ...

Page 2: ...made by children without supervision According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do...

Page 3: ...who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating...

Page 4: ...tective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause the stack to collapse Warning indications on the air con...

Page 5: ...to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the electrical control box cover of the indoor unit or service panel of the outdoor unit and do the work required Inside the air conditioner are high voltage areas and rotatin...

Page 6: ...er will not be turned on by marking out of service near the circuit breaker for instance until qualified service person 1 arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact ...

Page 7: ...or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing inju...

Page 8: ... notice In case that cardboard boxes protrude out of pallet when stacking lay a 10 mm thick plywood over the pallet Indoor unit Air discharge Connect a discharge duct Air intake Air filter Drain pan Electrical control box The earth screw is provided in the electrical control box Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Air intake Side...

Page 9: ...d Auto High Med Low 9 Set temperature display The selected set temperature is displayed 10 Power saving mode display Limits compressor speed capacity to save energy 1 6 4 2 3 5 7 13 15 14 9 12 11 10 8 16 17 11 UNIT No display The selected indoor unit number is displayed Also number of indoor or outdoor unit which an error occurs is displayed 12 Central control display Displayed when the air condit...

Page 10: ...ntroller can also be sensed For details contact the dealer from which you have purchased the air conditioner 4 Correct usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation When the circuit breaker is turned on the partition lines ...

Page 11: ...ation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe proper operating hours and we recommend that you ask service staff for periodic maintenance of the air conditioner 5 Timer operation Three timer modes are availabl...

Page 12: ...mode To adjust the power save settings see To configure the power saving settings in Power saving mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places so be sur...

Page 13: ...e dealer where you purchased the product The switch does not work properly The circuit breaker often blows out You unintentionally put a foreign object or water inside The unit cannot be run even after the cause of the protective device activation is removed Other unusual conditions are found NOTE For environmental conservation it is strongly recommended that the indoor and outdoor units of the ai...

Page 14: ...peration During the defrosting operation the defrosted water will be drained from the bottom plate of the outdoor unit Heating capacity In the heating operation the heat is absorbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air condition...

Page 15: ...r in a place subject to combustion emissions Corrosion may be generated on the aluminum fin and copper pipe of the heat exchanger Do not install the air conditioner near an obstacle such as air vent lighting equipment that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision inst...

Page 16: ...MEMO OM_1116950248_EN indd 15 OM_1116950248_EN indd 15 22 6 2564 BE 16 14 22 6 2564 BE 16 14 ...

Page 17: ...OM_1116950248_EN indd 16 OM_1116950248_EN indd 16 22 6 2564 BE 16 14 22 6 2564 BE 16 14 ...

Page 18: ...44 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116950248 OM_1116950248_EN indd 17 OM_1116950248_EN indd 17 22 6 2564 BE 16 14 22 6 2564 BE 16 14 ...

Reviews: