5. SPECIFICATIONS OF ELECTRICAL PARTS
Outdoor Unit
No.
Parts name
Type
Specifications
1
Compressor
RX330A2T-20M
2
Outdoor fan motor
WDF-340-A100-1
Output 100W
3
High pressure switch
ACB-4UB83W
ON : 3.2MPa, OFF : 4.15MPa
4
PMV-Coil
CAM-MD12TCTH-7
DC12V
6
Reactor
CH-55-2Z-T
5.4~6.14mH, 14A
7
P.C.board for control and fan motor drive
MCC-1626
—
8
P.C.board for compressor drive
MCC-1627
—
9
Outdoor temp. sensor (TO sensor)
—
10 k
Ω
at 25°C
10
Discharge temp. sensor (TD sensor)
—
50 k
Ω
at 25°C
11
Suction temp. sensor (TS sensor)
—
10 k
Ω
at 25°C
12
Heat exchanger sensor (TE sensor)
—
10 k
Ω
at 25°C
14
Fuse (Mounted on P.C.board, MCC-1626)
50T 100H
T10A, 250V
15
Fuse (Mounted on P.C.board, MCC-1626)
50T(P) 063HFGF-001C4
T6.3A, 250V
16
Fuse (Mounted on P.C.board, MCC-1626)
SCT 3.15A
3.15A, 250V
17
Fuse (Mounted on P.C.board, MCC-1627)
FJL 250V 6.3A
T6.3A, 250V
18
Fuse (Mounted on P.C.board, MCC-1627)
GAC1 31.5A
31.5A, 500V
19
PTC Thermistor
MZ32-101RMARD01E
100
Ω
, 500V
5
Coil-value-4way
STF-H01AJ1872A1
AC220V ~ 240V
13
Heat exchanger sensor (TL sensor)
—
50 k
Ω
at 25°C
Output 3000W
FILE NO.SVM-18044
- 25 -