17
–
REMOTE CONTROLLER
QUIET
Remote Controller
Infrared Rays, 36.7kHz
Hi-POWER
SLEEP (1, 3, 5, 9 OFF TIMER)
COMFORT SLEEP
ECO
Louver Direction Setting
Louver AUTO Swing
OFF TIMER Setting
ON TIMER Setting
Fan Speed Selection
Thermo. Setting
Operation Mode Selection
AUTO, COOL, DRY, HEAT
Functions
• Cold draft preventing Function
• 3-minute Delay at Restart
for Compressor
• Fan Motor Starting Control
• Processing
(Temperature Processing)
• Timer
• Serial Signal Communication
• Clean Function
Heat Exchanger Sensor (Tc)
Room Temperature Sensor (Ta)
Infrared Rays Signal Receiver
and Indication
Initializing Circuit
Power Supply Circuit
Heat Exchanger Sensor (Tcj)
Converter (D.C circuit)
Noise Filter
Clock Frequency
Oscillator Circuit
M.C.U.
From Outdoor Unit
220-240V ~50Hz
220V ~60Hz
Serial Signal Transmitter/Receiver
Serial Signal Communication
(Operation Command and Information)
Indoor Unit Control Unit
Louver Motor
Drive Control
Indoor Fan
Motor Control
Indoor
Fan Motor
Louver
Motor
QUIET
Operation (START/STOP)
8. CONTROL BLOCK DIAGRAM
Indoor Unit
FILE NO. SVM-12087