– 38 –
10. DRAIN-UP KIT (Option)
10-1. Instructions for Fitting out Drain-up Kit RB-F81E2
WARNINGS
• Ask an authorized dealer or qualified installation professional to install the drain-up kit.
Inappropriate installation may result in water leakage, electric shock or fire.
• Turn off the main power supply switch or breaker before attempting any electrical work.
Make sure all power switches are off. Failure to do so may cause electric shock.
• Connect the connecting cable correctly.
If the connecting cable is connected by wrong way, electric parts may be damaged.
• Please read through this instructions before fitting accessories.
10-1-1. Specifications
Indoor unit
48.7
70
200
166
64
34.75
*24.5
45
14
Indoor unit
Drain hose port
(O.D.: Ø19)
Drain tube port
(V.P20 O.D.: Ø26)
Drain-up kit
*
Be careful
with the gap!
245.5
170
11
52.5
90
10-1-2. Outline Drawing
*
NOTE : That the drain-up kit affixed to the indoor unit is 24.5 mm lower than the bottom of the indoor unit.
Model
Power supply
Power consumption
Discharge flow rate
Drain port dia.
Safety device
Weight
Outside dimensions
RB-F81E2
1Ø, 220-240V, 50Hz / 220V, 60Hz
9 / 8 (W)
450 / 530 (cc/min) (For 300 mm high pumping head)
VP20 (ID.: Ø20 mm, OD.: Ø26 mm)
Float switch
2 kg
Height 200 mm x Width 170 + 75.5 mm x Depth 90 mm