INSTALLATION DIAGRAM OF INDOOR UNIT
INSTALLATION DIAGRAM OF INDOOR UNIT
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side :
∅
6.35 mm
Gas side
:
∅
9.52 mm
(RAS-B10,
13U2FVG-E)
:
∅
12.7 mm
(RAS-B18U2FVG-E)
One
each
B
Pipe insulating material
(polyethylene foam, 8 mm thick)
1
C
Putty, PVC tapes
One
each
Optional Installation Parts
3
Batteries
8
Pan head
wood screw
4
Remote control holder
Do not allow the drain hose to get
slack.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
Cut the piping
hole sloped
slightly.
Right
Rear right
Left
Bottom right
Rear left
Bottom left
Cut dot-line area
In case of right or left piping
7
Mounting screw
9
Insulation sheet
2
Wireless remote control
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
6