background image

(700)

(600)

272

560

670

240

340

Concealed Installation

The special method to install the indoor unit bury in the wall is shown here. 
Please make sure to change to wall burying mode.

1. To switch to the wall burying mode 
    To switch to the wall burying mode, press and hold AIR OUTLET 

SELECT button for 20 seconds.
-  When the operation set up and 5 beep sounds. Then indication at 

Temperature indicator will light up for 5 seconds.

-  To cancel, press AIR OUTLET SELECT button for 20 seconds then, 5 

beep sounds. Then indication at Temperature indicator will blinks for 5 
seconds.

-  To prevent dewfall, above plate angle should be narrow.

3. Installation using the supporting plate

  To install into the existing wall hole, if it is impossible to keep 20-30 mm 

of depth, use the supporting plate for securing the distance.

  Arrange the screw positions and supporting plate as shown in the 

fi gure.

  Be sure to switch to wall burying mode. 

(Rear screws potion)

(Field supply)

: Screw holes

(Field supply)

(Unit : mm)

Wall burying mode

For prevent dewfall

2. Wall hole size 
   Wall hole size should be enough to keep the distance with indoor unit as 

shown in the following fi gure.

50 or more

Indoor unit

50 or more

(Front view)

70 or more

800 or more

Wall

Floor

670 or more

20 to 30

240 to 250

Floor

Wall

(Side view)

(Unit : mm)

4. In case of lattice establishment

  Follow the following fi gure, make sure to keep enough distance 

between lattice, frame and wall.

  Be sure to switch to wall burying mode.

  The lattice should be make of wood.

  Between the air inlet and outlet, should be devided with partition board.

  Be sure to establish the open part for RECEIVER.

  The open part of lattice must be opens 70 % or more of the wall hole.

  The open part of lattice must be arranged uniformly.

(Top view)

Partition board

(Unit : mm)

(Side view)

NOTE

  In case the plinth is fi xed to the wall, please make sure to cut out the slit 

on the left and right side of the main part.

Mounting directly on the fl oor.

1) Fix the leg of indoor unit on the fl oor with 2 mounting screws.
2) Fix the upper part of indoor unit on the wall with 4 mounting screws.

Cut dot-line area

Slit

6 screw
(M4 x 25L)

Installation on the wall

1) Fix the installation plate on the wall with 4 mounting screws.
2) Hook the indoor unit on the installation plate.
3) Fix the upper part of indoor unit on the wall with 4 mounting screws.

(Floor installation)

CAUTION

Make sure to fi x it at a designated position with the screws.
Failure may result the damage of piping by the turning over of a set.

(Wall installation)

230

150

10

15

15

40

288

670

1000 mm or less

4 screw
(M4 x 25L)

4 screw
(M4 x 25L)

EN

ES

FR

IT

PT

PL

CZ

RU

CR

HU

TR

NL

GR

SV

FI

NO

DK

RO

BG

EE

LV

SK

SI

DE

9

Summary of Contents for RAS-B10U2FVG-E

Page 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL Indoor unit RAS B10 13 18U2FVG E R32 1112151199 ...

Page 2: ...tallation Parts 6 INDOOR UNIT 7 Installation Place 7 Cutting a Hole and Mounting Installation Plate 7 How to Install Indoor Unit 8 Concealed Installation 9 OTHERS 10 Gas Leak Test 10 Setting of Remote Control Selector Switch 10 Remote Control A B Selection 10 Test Operation 10 Auto Restart Setting 10 EN ...

Page 3: ...e of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations CAUTION This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles DANGER FOR USE BY QUALIFIED PERSONS ONLY TURN O...

Page 4: ...ght of the unit Personal injury and property damage can result if the unit falls Before doing the electrical work attach an approved plug to the power supply cord Also make sure the equipment is properly earthed Appliance shall be installed in accordance with national wiring regulations If you detect any damage do not install the unit Contact your dealer immediately Do not use any refrigerant diff...

Page 5: ... is the refrigerant charge amount in appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 1 0 m or less Comply with national gas regulations CAUTION Exposure of unit to water or other moisture before installation could result in electric sh...

Page 6: ...ation is not accepted by the supplier the service agency will take adequate countermeasures Important information regarding the refrigerant used This product contains fluorinated greenhouse gases Do not vent gases into the atmosphere Refrigerant type R32 GWP 1 value 675 ex R32 ref AR4 1 GWP global warming potential The refrigerant quantity is indicated on the unit name plate This value is based on...

Page 7: ...ille Filter Maintenance Shelf life Clean every 3 6 months when dust tuck or covers the filter 1 Recommend to use vacuum to clean by sucking the dusts which stick or dip inside the filter or use the blower to blow the dust go out through the filter 2 If necessary to use water to clean simply use the plain water to wash the filter dry with the sunlight for 3 4 hours or until it completely dry Nevert...

Page 8: ...ol holder Do not allow the drain hose to get slack Make sure to run the drain hose sloped downward The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Insulate the refrigerant pipes separately with insulation not together 8 mm thick heat resisting polyethylene foam Cut the piping hole sloped slightly Right Rear right Left Bottom right Rear left ...

Page 9: ...hole brim ring sold separately A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened In case of block brick concrete or similar type walls make 5 mm holes in the wall Insert clip anch...

Page 10: ... Do not form the drain hose into a wavy shape Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Drainage 1 Run the drain hose sloped downwards Wiring connection Wiring of the connection cable is necessary to remove the front panel 1 Remove the terminal cover and cord clamp 2 Insert the connecting cable according to the local rule into the pipe hole on the...

Page 11: ...or more 20 to 30 240 to 250 Floor Wall Side view Unit mm 4 In case of lattice establishment Follow the following figure make sure to keep enough distance between lattice frame and wall Be sure to switch to wall burying mode The lattice should be make of wood Between the air inlet and outlet should be devided with partition board Be sure to establish the open part for RECEIVER The open part of latt...

Page 12: ...y Remote Control B Setup 1 Push and hold button on the Remote Control by the tip of the pencil 00 will be shown on the display Picture 1 2 Press during pushing B will show on the display and 00 will disappear and the air conditioner will turn OFF The Remote Control B is memorized Picture 2 Note 1 Repeat above step to reset Remote Control to be A 2 Remote Control A has not A display 3 Default setti...

Page 13: ...1112151199 ...

Reviews: