32
–
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH
: Ultra High
H
: High
M+
:
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate
+2.5
Ta
[˚C]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)
FILE NO. SVM-1
500
6
RAS-B10N3KV2-E1
RAS-B13N3KV2-E1
Cooling
Heating
Cooling
Heating
Fan speed Air flow rate
(rpm)
(m3/h)
Fan speed Air flow rate
(rpm)
(m3/h)
Fan speed Air flow rate
(rpm)
(m3/h)
Fan speed Air flow rate
(rpm)
(m3/h)
WF
UH
1120
515
1200
565
1300
627
1300
627
WE
UH
H
1120
515
1200
565
1300
627
1300
627
WD
H
M+
UH
1120
515
1100
502
1200
565
1190
558
WC
M+
H
1040
465
1000
440
1090
496
1080
490
WB
M
M+
1000
440
1000
440
1080
490
1080
490
WA
M
M
960
415
870
359
980
428
980
428
W9
L+
900
378
870
359
980
428
980
428
W8
L+
L
L+
860
353
750
284
880
365
870
359
W7
L
L-
780
303
700
253
770
297
770
297
W6
L-
L
650
222
650
222
770
297
770
297
W5
UL
UL
L-
620
203
650
222
720
266
720
266
W4
UL
600
191
520
141
690
247
690
247
W3
SUL
SUL/SL-
580
179
520
141
670
235
670
235
W2
SUL
540
154
520
141
520
141
520
141
W1
500
129
500
129
500
129
500
129
RAS-B16N3KV2-E1
Cooling
Heating
Fan speed Air flow rate
(rpm)
(m3/h)
Fan speed Air flow rate
(rpm)
(m3/h)
WF
UH
1510
758
1510
758
WE
UH
H
1480
730
1510
758
WD
H
M+
UH
1430
708
1480
730
WC
M+
H
1280
615
1430
708
WB
M
M+
1280
615
1280
615
WA
M
M
1150
534
1220
577
W9
L+
1100
502
1150
534
W8
L+
L
L+
980
428
1000
440
W7
L
L-
920
390
980
428
W6
L-
L
900
378
920
390
W5
UL
UL
L-
840
340
900
378
W4
UL
840
340
840
340
W3
SUL
SUL/SL-
770
297
770
297
W2
SUL
620
203
620
203
W1
520
141
520
141
Fan speed
level
Fan speed
level
Cool
Heat
Dry
Mode
Mode
Cool
Heat
Dry