– 68 –
Item
Operation flow and applicable data, etc.
Description
12. Temporary
operation
Pushing [RESET] button starts the temporary
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more,
the temporary [COOL] operation is performed.
1) When pushing [RESET] button, the temporary
[AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, “beep, beep, beep” sound is
heard and [AUTO RESTART] control is changed.
3) When keeping [RESET] button pushed for
10 seconds or more, “beep” sound is heard and
the temporary [COOL] operation starts.
4) If the filter lamp goes on, push [RESET] button to
go off the filter lamp, and then push [RESET]
button again.
5) To stop the temporary operation, push the button
again.
13. Air purifying control
1. Purpose
This function generates negative ion while
cleaning the air in the room.
The air purifying control function is to alert the
user that something is wrong in the ionizing or air
purifying operation.
If air purifier-ON signal is received while the air
conditioner stops, the air purifier starts operation,
and if it is received while the air conditioner
operates, the air conditioner and the air purifier
start operation.
The air ion generator operates linked with the air
purifying operation.
NOTE
When the previous operation was the operation of air condi air purifier, an operation of air condi air purifier
starts by pushing AC button on the remote controller. (Operation of air condi air purifier is stored in memory.)
PURE indicator (Orange) ON
Push RESET button.
Did you push [RESET] button
for 3 seconds or more?
Did you push [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
Present status
Operation
PURE button
Air conditioner
Stop
Air purifier
AC operation*
Air purifier only
Stop (All)
AC + Air purifier
Air conditioner
AC + Air purifier
All stop
Joint use of AC and air purifier
AC operationAC
All stop
Louver swing is available
Fan speed *1
Air purifying operation
Cooling position
AUTO, L, L+, M, M+, H
AC + Air purifying operation
Follows to AC operation
Follows to AC operation
0
8
15
30
min
Sending air purifier-ON
Sending air purifier-OFF
[1], [2]
[3], [4]
[1] Air conditioner stops
[2] Air conditioner
operates
[3] Air purifier operates
[4] Air condi
Air Purifier operation
Operation indicator ON
PURE indicator ON
Operation indicator OFF
PURE indicator OFF
PURE indicator ON
Moving panel Open
Fan ON
Air purifier ON
Air purifier ON
PURE indicator OFF
Air purifier OFF
1
Louver Open memory
position (Cooling)
Fan OFF
Air purifier OFF
Louver close
All stop
WC (WF)
W7 (WA)
W5 (W7)
W2 (W3)
Fan speed level
( ) : Hi Power
Air conditioner operates
Air purifying operation
Air condi
air purifier operation
1 Fan speed at Fan Auto mode.
∗
∗
∗
∗
∗
∗
∗
+00A10-023_01EN.book Page 68 Wednesday, April 6, 2011 2:43 PM