Item
15.
S
elf-Cleaning
function
Operation flow and applicable data, etc.
•
Self-Cleaning diagram
Description
1
6
.
Self-Cleaning
function release
Operation display
ON
OFF
OFF
FCU fan
ON
ON
OFF
rpm is depend on presetting.
(240RPM)
Upper airoutlet
OPEN
OPEN (11º)
CLOSE
Timer display
ON or OFF
ON
ON or OFF
depend on presetting of timer function.
depend on presetting of timer function.
Compressor
ON or OFF
OFF
OFF
depend on presetting per room temperature.
CDU fan
ON or OFF
OFF
OFF
depend on presetting per room temperature.
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning mode
operate 30 mins.
Automatically turn-off.
Operation time
Turn off by remote controller or
timer-off function.
How to cencel Self-Cleaning function
To cancel the Self-Cleaning function, proceed as
follows:
�
Press and hold [MODE] button on opreation
panel for more than 10 seconds.
(less than 20 seconds)
Lower airoutlet
OPEN or CLOSE
OPEN or CLOSE
depend on airoutlet selection
depend on airoutlet selection
OPEN or CLOSE
depend on airoutlet selection
�
After holding about 10 seconds, the air conditioner
beep 4 times without any blinking of display.
�
After releasing [Mode] button, Self-Cleaning
function is cancelled.
How to set Self-Cleaning function
To set the Self-Cleaning function, proceed as
follows:
�
Press and hold [MODE] button on opreation
panel for more than 10 seconds.
(less than 20 seconds)
�
After releasing [Mode] button, Self-Cleaning
function is set.
�
After holding about 10 seconds, the air conditioner
beep 4 times and OPERATION display blinks
5 seconds.
- 47 -