4
Toshiba 1115551210 (EN)
m from the right side edge is
e
center of pipe hole
35
120
180
240
INDOOR UNIT
INDOOR UNIT
The center of the pipe hole is
above the arrow.
Pipe hole
Installation Place
Remote control
•
A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
•
Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
•
Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment (This is necessary to prevent image disturbances or
noise interference).
•
The location of the remote control should be determined as shown below.
Cutting a Hole and Mounting
Installation Plate
NOTE
•
When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
•
A place which provides the spaces around the indoor unit as shown in the
diagram.
•
A place where there are no obstacles near the air inlet and outlet.
•
A place which allows easy installation of the piping to the outdoor unit
•
A place which allows the front panel to be opened.
•
The indoor unit shall be installed as top of the indoor unit comes to at
least 2 m height. Also, it must be avoided to put anything on the top of the
indoor unit.
Cutting a hole
When installing the refrigerant pipes from the rear
CAUTION
•
Direct sunlight to the indoor unit’s wireless receiver should be avoided.
•
The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner’s manual).
1. After determining the pipe hole position on the mounting plate (
A
), drill
the pipe hole (
∅
65 mm) at a slight downward slant to the outdoor side.
When the installation plate is directly mounted
on the wall
1. Securely fi t the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below fi gure.
3. Install the installation plate horizontally in the wall.
•
In case of block, brick, concrete or similar type walls, make 5 mm dia.
holes in the wall.
•
Insert clip anchors for appropriate mounting screws
7
.
Installation plate
(Keep horizontal direction.)
5 mm dia. hole
Clip anchor
(local parts)
Anchor bolt
Projection
15 mm or less
Mounting the installation plate
NOTE
•
Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
7
Mounting screw
∅
4 x 25
s
CAUTION
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
CAUTION
When installing the installation plate with a mounting screw, do not use
the anchor bolt holes. Otherwise, the unit may fall down and result in
personal injury and property damage.
To unit out line
240mm
To unit out line
35mm
To unit out line
240mm
Of
fset 23mm from the right side edge is
the center of pipe hole
To unit out line
120mm
0
23
35
120
180
240
Of
fset 85mm from the left side edge is
the center of pipe hole
170
170
5
0
4
0
85
132
23
Hook
Hook
Hook
Pipe hole
Pipe hole (
∅
65 mm)
Weight
Indoor unit
Thread
2 m or more from fl
oor
Anchor bolt holes
1
Installation plate
7
Mounting
screw
5
4
45
5
7
Indoor unit
(Side view)
(Top view)
Indoor unit
Remote control
Remote
control
Reception
range
Reception range
∅
65 mm
23 mm
∅
65 mm
TSB 1115551210_EN.indb 4
TSB 1115551210_EN.indb 4
6/18/14 9:03 AM