FILE NO. SVM-02009
– 18 –
5-4. RAS-24UFP-ES / RAS-24UA-ES
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Standard
0.9
11.0
High
27/19
35/24
Cooling
High temperature
0.8
12.0
High
32/23
43/26
Low temperature
0.5
1.0
Low
21/15
21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Evaporator
Indoor unit
Multi blade fan
Compressor
Condenser
Tank
Propeller fan
Outdoor unit
Capillary tube
∅
2.0x600
S
PA290X3F-4MS
Cooling
O.D.:6.35 mm
Packed valve
(
∅
12.70 )
Packed valve
(∅
6.35)
0.49m
(Connecting pipe)
∅
6.35 mm
T
P
Refrigerant
R-410A 1.60 Kg
Mark ( ) means check points of Gas Leak
O.D.:12.70 mm
Cooling
0.39m
(Connecting pipe)
∅
12.70 mm
∅
12.70 mm
0.39m
(Flexible pipe)