background image

PRESET OPERATION

14

Set your preferred operation for future use. The setting will be memorized by the 

unit for future operation (except air

fl

 ow direction).

  1. Select your preferred operation.

  2. Press and hold 

PRESET

 for 3 seconds to memorize the setting. The 

P

 mark 

displays.

 3. 

Press 

PRESET

 : Operate the preset operation.

AUTO RESTART OPERATION

15

To automatically restart the air conditioner after the power failure (Power of the 
unit must be on.)

Setting

  1. Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 
seconds)

    • Do not operate ON timer and OFF timer.
  2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel 

the operation. (3 beep sound but OPERATION lamp does not blink)

To operate at super low fan speed for quiet operation (except in DRY mode)

 Press 

QUIET

 : Start and stop the operation.

 

Note:

  Under certain conditions, QUIET operation may not provide adequate 

cooling due to  low sound features.

QUIET OPERATION

16

For comfortable sleep, automatically control air 

fl

 ow and automatically turn OFF.

 Press 

COMFORT

SLEEP

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

 

Note:

  The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase).

COMFORT SLEEP OPERATION

17

OPERATION AND PERFORMANCE

21

  1. Three-minute protection feature: To prevent the unit from being activated for 

3 minutes when suddenly restarted or switched to ON.

  2. Some minor cracking sound may occur when unit operating. This is normal 

because the cracking sound may be caused by expansion/contraction of 

plastic.

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room

Temperature

Cooling

21°C ~ 43°C

21°C ~ 32°C

Dry

21°C ~ 43°C

21°C ~ 32°C

The unit does not operate.

Cooling is abnormally low.

•  The power main switch is turned off.
•  The circuit breaker is activated to 

cut off the power supply.

•  Stoppage of electric current.
•  ON timer is set.

• The 

fi

 lters are blocked with dust.

•  The temperature has been set 

improperly.

•  The windows or doors are opened.
•  The air inlet or outlet of the outdoor 

unit is blocked.

•  The fan speed is too low.
•  The operation mode is FAN or DRY.

TROUBLESHOOTING (CHECK POINT)

22

To start the sleep timer (OFF timer) operation
 Press 

SLEEP

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

SLEEP TIMER OPERATION

18

REMOTE CONTROL A-B SELECTION

23

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold 

CHK 

 button on the Remote Control by the tip of the pencil. 

“00” will be shown on the display.

 4. 

Press 

MODE

 during pushing 

CHK 

. “B” will show on the display and “00” will 

disappear and the air conditioner will turn OFF. The Remote Control B is 
memorized.

Note:

 1. Repeat above step to reset Remote 

Control to be A.

 

2. Remote Control A has not “A” display.

 

3. Default setting of Remote Control from 

factory is A.

SELF CLEANING OPERATION (COOL AND 
DRY OPERATION ONLY)

20

To protect bad smell caused by the humidity in the indoor unit.

 1. 

If 

the   button is pressed once during “Cool” or “Dry” mode, the fan will continue 

to run for other 20 minutes, then it will turn off automatically. This will reduce 

the moisture in the indoor unit.

  2. To stop the unit immediately, press the   3 times within 30 seconds.

Note:

  •  SELF CLEANING operation is default setting from factory.

  •  To cancel this function, please contact the supplying retail dealership.

Cleaning the plasma air puri

fi

 er unit (About 1000 hours performed) 

(SKDX Only)

  1. Turn off air conditioner using remote control and power supply.
  2. Take out the air inlet grille (See detail in installation manual).
  3. Take out the plasma air puri

fi

 er by grasp the handle, and the pull it out.

  4. Soak in hot water at 40

o

C to 50

o

C for about 10 to 15 minutes and rub up, 

down, left, right and rub surface gently with a sponge.

  5. Allow to dry thoroughly in the shade.
  6. Attach the plasma air puri

fi

 er by grasp the handle and 

insert into the right and left guide rails.

  7. Press both ends of the plasma air puri

fi

 er until the 

protrusions on both sides of the plasma air puri

fi

 er 

are completely inserted.

  8. Attach the air 

fi

 lter, and then close the air inlet grille.

 Firstly, turn off the circuit breaker.

Filter Reset (Some models only)

FILTER lamp lights on; the 

fi

 lter must be cleaned.

To turn off the lamp, push the RESET button on the indoor unit or the FILTER 
button on the remote control.

Indoor Unit and Remote Control

  •  Clean the indoor unit and the remote control with a wet cloth when needed.
  •  No benzine, thinner, polishing powder or chemically-treated duster.

Cleaning the air ionizer (Once every six months) (SKDX Only)

  1. Turn off air conditioner using remote control and power supply.
  2. Fully open the vertical air 

fl

 ow louvers by hand.

  3. Use a toothbrush to rub the ends of metal pin 

three or four times.

 Note:

  Do not use cotton swabs or other objects 

with 

fl

 uff.

   

Even before 6 months since last cleaning, 
clean the air ionizer if it is dirty.

MAINTENANCE

19

1110650101.indb   4

1110650101.indb   4

3/11/08   4:46:25 PM

3/11/08   4:46:25 PM

Summary of Contents for RAS-18SK Series

Page 1: ... FI NO DK RO BG EE LV SK SI OWNER S MANUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 18 24 SK Series Outdoor unit RAS 18 24 S Series ENGLISH ภาษาไทย 1110650101 indb 1 1110650101 indb 1 3 11 08 4 46 10 PM 3 11 08 4 46 10 PM ...

Page 2: ...n the power cable expose it to heat or pull it To do so may cause electrical shock or fire CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly installed it may cause an electric shock To check the installation method please contact the supplying retail dealership or the professional vendor who installed the unit When using the unit in a closed room ...

Page 3: ...rees increase REMOTE CONTROL 4 1 Infrared signal emitter 2 Start Stop button 3 Mode select button MODE 4 Temperature button TEMP 5 Fan speed button FAN 6 Swing louver button SWING 7 Set louver button FIX 8 On timer button ON 9 Off timer button OFF Sleep timer button SLEEP Setup button SET Clear button CLR Memory and Preset button PRESET One Touch button ONE TOUCH High power button Hi POWER Economy...

Page 4: ...lled nearly Remote Control B Setup 1 Press RESET button on the indoor unit to turn the air conditioner ON 2 Point the remote control at the indoor unit 3 Push and hold CHK button on the Remote Control by the tip of the pencil 00 will be shown on the display 4 Press MODE during pushing CHK B will show on the display and 00 will disappear and the air conditioner will turn OFF The Remote Control B is...

Page 5: ...อากาศในห องป ด หรือใช ร วมกับอุปกรณ ที มีการเผาไหม อื นๆ ควร เป ดหน าต างเป นระยะเพื อให มีอากาศไหลเวียนเพียงพอ มิฉะนั นอาจเกิดอาการขาดอากาศ เนื องจากออกซิเจนไม เพียงพอได หลีกเลี ยงการใช งานเครื องปรับอากาศเป นเวลานานในที ที มีความชื นสูง มากกว า 80 เช น ใช งานขณะเป ดหน าต างหรือประตู เพราะอาจเกิดการควบแน นภายในเครื องจนมีหยด น ำไหลออกมาเป อนเฟอร นิเจอร ได หากจะไม ใช เครื องปรับอากาศเป นเวลานาน ให...

Page 6: ... างเดียว 7 1 กดปุ ม MODE เลือกความเย น หรือพัดลมอย างเดียว 2 กดปุ ม TEMP ตั งอุณหภูมิที ต องการ การทำความเย น 17 C พัดลมอย างเดียว ไม มีการแสดงอุณหภูมิ 3 กดปุ ม FAN เลือก AUTO LOW LOW MED MED หรือ HIGH ระบบลดความชื น 8 ในการลดความชื น จะมีการควบคุมสมรรถนะในการทำความเย นโดยอัตโนมัติ 1 กดปุ ม MODE เลือกระบบลดความชื น 2 กดปุ ม TEMP ตั งอุณหภูมิที ต องการ ระบบฟอกอากาศ เฉพาะรุ น SKDX เท านั น 9 กด PURE...

Page 7: ...เอียดในคู มือการติดตั ง 3 จับที ด ามจับของตัวฟอกอากาศพลาสมาแล วดึงออกมา 4 นำไปแช ในน ำร อนอุณหภูมิ 40 C ถึง 50 C เป นเวลาประมาณ 10 ถึง 15 นาที แล ว จึงขัดขึ นลง และขัดไปทางซ ายและทางขวาจากนั นขัดผิวตัวฟอกอากาศด วยฟองน ำ 5 ตากให แห งสนิทในที ร ม 6 ติดตั งตัวฟอกอากาศพลาสมากลับเข าที โดยจับที ด ามจับแล วเสียบเข าไปที รางตัวนำโดย เริ มที ด านขวาก อนแล วตามด วยด านซ าย 7 กดปลายทั งสองข างของตัวฟอกอากาศ...

Page 8: ...1110650101 1110650101 indb 08 1110650101 indb 08 3 11 08 4 46 29 PM 3 11 08 4 46 29 PM ...

Reviews: