background image

Toshiba 1112150101 (EN)

EN

ES

FR

IT

PT

PL

CZ

RU

CR

HU

TR

NL

GR

SV

FI

NO

DK

RO

BG

EE

LV

SK

SI

DE

20

  REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

1.  Push and hold 

 button on the Remote Control by the tip of the pencil.

   “00” will be shown on the display.

2.  Press 

 during pushing 

. “B” will show on the display and “00” will 

disappear and the air conditioner will turn OFF. The Remote Control B is 
memorized.

Note: 

1.  Repeat above step to reset Remote 

 

 

Control to be A.

  

2.  Remote Control A has not “A” display.

  

3.  Default setting of Remote Control from 

 

 

factory is A.

Unit B setup. 

  Press and hold MODE button for more than 20 seconds. 
  When A setup changed to B setup : 5 beeps will sound and operation lamp 

blinks for 5 seconds. 

  When B setup changed to A setup : 5 beep will sound.

21

  ADJUSTING BRIGHTNESS OF 

 

UNIT DISPLAY PANEL

1. Press and hold AIR OUTLET SELECT button then press MODE button for 

3 times (All lamp of the unit display panel will be switched on).   

  (At that time, please press and hold the AIR OUTLET SELECT button)
2. Press and hold AIR OUTLET SELECT button on Unit display panel, then 

press TEMPERATION button (Up), (Down) for select the desired brightness.

3. Brightness will be settled when AIR OUTLET SELECT button is released.
  Although the temperature indicator is switched off, if press the temperature 

button (up) and (down), the set temperature will be indicated, and then can 
adjust the temperature.
10 seconds after stopped pressing the button, the temperature indication will 
be switched off.

4 stages of brightness can be changed.

Temperature indicator

Other lamp

1

Usual

Usual

2

Darkness

Darkness

3

Turn off

Darkness

4

Turn off

Turn off

Note: 

When there is an abnormality in the product, abnormal code (2 digits) will  

 

be displayed on the unit display panel. Please contact the dealership.

In case of multiple connection

•   Check whether the operation mode is different from what has been selected 

for the units in the other rooms (The following combinations of operations 
cannot be performed: COOL and HEAT, DRY and HEAT).

•  Select the same operation mode as for the other rooms.

22

  CHANGE AIR OUTLET GRILLE ON 

 

STABLE TIME (COOLING ONLY)

On cooling operation, whichever air outlet is set, only Upper is used when the 
room temperature approaches the set temperature.
In case to keep up/down blowing, operate as below;
Press and hold AIR OUTLET SELECT button for more than 10 seconds (less than 
20 seconds) (4 beeps will sound then “1” indication at TEMPERATURE indicator 
will light up for 5 seconds).
For return to the former status, press and hold AIR OUTLET SELECT button 
for more than 10 seconds once again (In this time, 4 beeps will sound then “0” 
indication at TEMPERATURE indicator will blinks for 5 seconds).

23

  AIR INLET GRILLE MAINTENANCE

Wash the air inlet grille with water using the soft sponge or towel.

•   Dry it well in a shadow area after washing.
•   Scour heavy dirt with neutral detergent for kitchen, and rinse it with the water 

(Do not use the wire wool).

•   Do not press the front panel strongly. It may be cracked.

The unit does not operate.

Cooling or Heating is abnormally low

•   The power main switch is 

turned off. 

•   The circuit breaker is activated 

to cut off the power supply. 

•   Stoppage of electric current. 
•   ON timer is set. 

•   The fi lters are blocked with dust.
•   The temperature has been set 

improperly.

•   The windows or doors are opened.
•   The air inlet or outlet of the outdoor 

unit is blocked.

•   The fan speed is too low.
•   The operation mode is DRY.

19

  TROUBLESHOOTING (CHECK POINT)

Summary of Contents for RAS-18SAV Series

Page 1: ... SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA OWNER S MANUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS B 10 13 18UFV Series Outdoor unit RAS 10 13 18SAV Series RAS M14GAV E RAS M18GAV E RAS 3M18SAV E RAS 3M26GAV E1 RAS 4M23SAV E RAS 4M27GAV E1 RAS 5M34UAV E ...

Page 2: ...ock injury or water leakage Do not disassemble modify or relocate the unit by yourself It may become the cause of fire electric shock or water leakage For repair or relocation please request service from the supplying retail dealership or a dealership When relocating or repairing the unit please contact the supplying retail dealership When there is a kink in the wiring it may be the cause of elect...

Page 3: ...tilation may cause suffocation due to a lack of oxygen Do not use combustion appliances in the direct flow of the air from the air conditioning unit Poor combustion of a combustion appliance may cause suffocation Avoid operating for long periods in a high humidity environment over 80 such as with the windows or doors open There may be condensation on the indoor unit and droplets may fall onto the ...

Page 4: ...T Comfort sleep button COMFORT SLEEP Filter reset button FILTER Clock Reset button CLOCK Check button CHK Floor warming mode button FLOOR 1 OPERATION button Unit operation ON OFF button turn off FILTER CHECK Indicator 2 MODE button Operation mode Auto Cooling Heating Auto CHILD LOCK function Press MODE button for 3 seconds It is possible to operate even when stopping To cancel CHILD LOCK function ...

Page 5: ...ration is started automatically and the TIMER indicator on the unit s display panel turns on Cleaning operation duration The cleaning operation lasts for 30 minutes if the unit has been operating in the cooling or dry mode for 10 minutes or more Note SELF CLEANING operation is default setting from factory How to cancel SELF CLEANING operation Press and hold MODE button on operation panel for more ...

Page 6: ... Darkness 3 Turn off Darkness 4 Turn off Turn off Note When there is an abnormality in the product abnormal code 2 digits will be displayed on the unit display panel Please contact the dealership In case of multiple connection Check whether the operation mode is different from what has been selected for the units in the other rooms The following combinations of operations cannot be performed COOL ...

Page 7: ...THAILAND CO LTD Address city country 144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU TOSHIBA CARRIER UK LTD Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: