– 67 –
FILE NO. SVM-08032
1) Perform the common procedure
1
2) Remove the capacitor band. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (2 screws
∅
4 x 18L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (1 screws
∅
4 x 10L)
3) Disconnect the lead wires from the terminal.
2
Running
capacitor
for compressor
3
Running
capacitor
for fan motor
4
Magnetic
contactor
5
Spark killer
Spark killer
Running capacitor
for compressor
Running capacitor
for fan motor
Magnetic contactor
Procedures
Remarks
Part name
No.