OPERATION AND PERFORMANCE

18

The unit does not operate.

Cooling or Heating is abnormally low.

 

The power main switch is 
turned off.

 

The circuit breaker is activated 
to cut off the power supply.

 

Stoppage of electric current

 

ON timer is set.

 

The 

fi

 lters are blocked with dust.

 

The temperature has been set 
improperly.

 

The windows or doors are opened.

 

The air inlet or outlet of the outdoor 
unit is blocked.

 

The fan speed is too low.

 

The operation mode is FAN or DRY.

TROUBLESHOOTING (CHECK POINT)

19

REMOTE CONTROL A-B SELECTION

20

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.

3. Push and hold 

 button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display. (Picture 

1

)

4. Press 

02'(

 during pushing 

. “B” will show on the display and 

“00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized. (Picture 

2

)

Note:

  1. Repeat above step to reset Remote Control to be A.

 

2. Remote Control A has not “A” display.

 

3. Default setting of Remote Control from factory is A.

1.  Three-minute protection feature: To prevent the unit from being 

activated for 3 minutes when suddenly restarted or switched to ON.

2.  Preheating operation: Warm up the unit for 5 minutes before the heating 

operation starts.

3.  Warm air control: When the room temperature reaches the set 

temperature, the fan speed is automatically reduced and the outdoor 
unit will stop.

4.  Automatic defrosting: Fans will stop during defrost operation.
5.  Heating capacity: Heat is absorbed from outdoors and released into 

the room. When the outdoor temperature is too low, use another 
recommended heating apparatus in combination with the air conditioner.

6.  Consideration for accumulated snow: Select the position for outdoor unit 

where it will not be subjected to snow drifts, accumulation of leaves or 
other seasonal debris.

7.  Some minor cracking sound may occur when unit operating. This is 

normal because the cracking sound may be caused by expansion/
contraction of plastic.

 

Note:

 Item 2 to 6 for Heating model 

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room Temperature

Heating

–15°C ~ 24°C

Less than 28°C

Cooling

–15°C ~ 46°C

21°C ~ 32°C

Dry

–15°C ~ 46°C

17°C ~ 32°C

Summary of Contents for RAS-18PAVSG-E

Page 1: ...ENGLISH ENGLISH OWNER S MANUAL R32 1120650201 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 18 22 24PKVSG E Outdoor unit RAS 18 22 24PAVSG E ...

Page 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of ex...

Page 3: ...appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 2 5 m CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or ...

Page 4: ...FORT SLEEP Filter reset button FILTER Set clock button CLOCK Check button CHECK Reset button RESET AUTOMATIC OPERATION 5 To automatically select cooling heating or fan only operation 1 Press 02 Select A 2 Press Set the desired temperature 3 Press 1 Select AUTO LOW LOW MED MED HIGH or Quiet 1 Press 02 Select Cool Heat or Fan only 2 Press Set the desired temperature Cooling Min 17 C Heating Max 30 C...

Page 5: ...does not activate For comfortable sleep automatically control air flow and automatically turn OFF Press Select 1 3 5 or 9 hrs for OFF timer operation Note The cooling operation the set temperature will increase automatically 1 degree hour for 2 hours maximum 2 degrees increase For heating operation the set temperature will decrease COMFORT SLEEP OPERATION 15 SELF CLEANING OPERATION COOL AND DRY OP...

Page 6: ...et Remote Control to be A 2 Remote Control A has not A display 3 Default setting of Remote Control from factory is A 1 Three minute protection feature To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON 2 Preheating operation Warm up the unit for 5 minutes before the heating operation starts 3 Warm air control When the room temperature reaches the set t...

Page 7: ...1120650201 ...

Reviews: