13
EN
1.
Run the drain hose at a downward sloped angle.
NOTE
• Hole should be made at a slight downward slant on the outdoor side.
2.
Put water in the drain pan and make sure that the water is being drained outside.
3.
When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.
This air conditioner has been designed to drain water collected from
condensation which forms on the back of the indoor unit, to the drain pan.
Therefore, do not locate the power cord and other parts at a height above the
drain guide.
Drainage
CAUTION
Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room.
Do not put the drain hose
end into water.
Do not route the
drain hose upwards.
Do not form the drain
hose into a waved shape.
50 mm or
more
Do not put the drain hose
end in a drainage ditch.
Shield pipe
Drain hose
Inside the room
Extension drain hose
Space for pipes
Drain guide
Wall