10. INSTALLATION PROCEDURE
10-1.
Installation Diagram of Indoor and Outdoor Units
1
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available,
provided by installer)
Shield pipe
(A
tta
ch t
o th
e fr
on
t p
an
el.)
Air fi
lter
Installation
plate
2
-9
/1
6
i
n
.
(6
5
m
m
)
o
r
m
o
re
7 in.
(170
mm
)
or m
ore
3-15
/16 i
n. (1
00 m
m)
or m
ore
3-1
5/1
6 in
. (1
00
mm
)
or m
ore
23
-5/
8 in
. (6
00
m
m)
or
mo
re
23-5
/8 in
. (60
0 m
m)
or m
ore
6
5
Filter
Filter
Hook
Hook
24 in. (600 mm) or more
only when unobstructed to
the front and both sides.
7 in.
(170
mm
)
or m
ore
Conduit
Front
panel
Air inlet grille
Insulate the refrigerant pipes separately,
not together.
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole slightly sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
5/16 in. (8 mm) thick heat
resisting polyethylene foam
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (
−
) positions.
3 Batteries
2 Wireless remote controller
A
C
L
2
3
Batteries
Wireless remote control
8
Flat head
wood screw
4
Remote control holder
–
47
–
Remark :
• Details of accessory and installation parts can
be found in the accessory section.