6
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø9.52 mm
(RAS-10,
13PKVSG-E)
:
Ø12.70
mm
(RAS-16PKVSG-E)
One
each
B
Pipe insulating material
(polyethylene foam, 6 mm thick)
1
C
Putty, PVC tapes
One
each
Optional Installation Parts
• Secure the outdoor unit with
fi
xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple
#
and cap
water proof
$
to the bottom plate of the outdoor unit before installing it.
Fixing bolt arrangement of outdoor unit
2
3
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
1
Batteries
7
Flat head
wood screw
4
Remote control
holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension drain hose
(Not available, provided
by installer)
Shield pipe
(Attach to the front panel.)
Air
fi
lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
600 mm or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
Drain outlet
Air inlet
Air outlet
108 mm
28 mm
600 mm
320 mm
125 mm
86 mm
102 mm
90 mm
Ø25 mm
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The
fl
are connection should be installed
outdoors.
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see “How to Connect The Remote
Controller for Wired Operation”, in case of
wired control is required.
5
Filter
!
Flat head
wood screw
7
Flat head
wood screw
"
Battery
cover
01_1118350131-EN.indd 6
01_1118350131-EN.indd 6
2/10/2560 BE 10:06 AM