Item
15. QUIET mode
Operation flow and applicable data, etc.
Description
When the [QUIET] button is pressed, the fan of the
indoor unit will be restricted the revolving speed at
−
until the [QUIET] button is pressed once
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
speed L
again (cancel Quiet mode).
Because of the fan speed L- may cause not
enough the cooling capacity or heating
16. COMFORT The principles of comfort sleep mode are:
•
Quietness for more comfortable. When
•
Save energy by changing room temperature
•
The air condition can shut down by itself
Remarks:
1. Comfort sleep mode will not operate in dry
automatically.
mode and fan only mode.
automatically.
room temperature reach setting temperature
Cooling mode
•
The preset temperature will increase as
show on ECO operation (Item No. 9)
•
Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to select the hours.
•
If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
Heating mode
•
The preset temperature will drop down as
show on ECO operation (Item No. 9)
choose the operating hours. Repeat
•
Press the [COMFORT SLEEP] button to
pressing to setect thehours.
•
If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
(1hr, 3hr, 5hr or 9hr)
(1hr, 3hr, 5hr or 9 hr)
.
−
41
−
capacity.
SLEEP mode
FILE NO. SVM-10015
17. One-Touch
0
12
25
AUTO
* AUTO/L
L
Fan
Operation
Time after operation
starts (min)
One touch comfort is the fully automated operation
that is set according to the preferable condition in
a region.
Comfort
*AUTO/L: Fan operates depends on the setting
temperature and room temperature.
During the One Touch Comfort mode if the indoor
unit receives any signal with other operation mode,
the unit will cancel the comfort mode and operates
according to the signal received.
Operation condition for model to Europe
market
When an indoor unit receives "One Touch
Comfort Signal" from the remote controller,
the indoor unit operates as following.
1) Air conditioner starts to operation when
the signal is received, even if the air
conditioner was OFF.
2) Operation mode is set according to room
temperature, the same as AUTO mode.
3) Target temperature is 24ºC.
4) Louver position is set as stored position
of the operating mode.
5) Fan is controlled as followings.