![Toshiba RAS-10UAV-E Service Manual Download Page 34](http://html.mh-extra.com/html/toshiba/ras-10uav-e/ras-10uav-e_service-manual_1135592034.webp)
FILE NO. SVM-02007
– 33 –
8-5. Hi POWER Mode ([Hi POWER] button
on the remote control is pressed.)
When [Hi POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi
POWER mark is indicated on the display of the remote
control and the unit operates as follows.
(1) Automatic operation
•
The indoor unit operates in according to the
current operation.
(2) Cooling operation
•
The preset temperature drops 1°C.
(The value of the preset temperature on the
remote control does not change.)
•
If the difference between the preset temperature
and the room temperature is big, the horizontal
louver moves to the Hi POWER position
automatically. Then when the difference between
them gets smaller, the horizontal louver returns
automatically.
(3) Heating operation
•
The preset temperature increases 2°C. (The
value of the preset temperature on the remote
control does not change.)
•
If the difference between the preset temperature
and the room temperature is big, the horizontal
louver moves to the Hi POWER position
automatically. Then when the difference between
them gets smaller, the horizontal louver returns
automatically.
(4) The Hi POWER mode can not be set in Dry or Fan
only operation.
8-6. Filter Check Lamp
When the elapsed time reaches 1000 hours, the filter
check lamp indicates. After cleaning the filters, turn off
the filter check lamp.
8-6-1. How to turn off filter check lamp
(1) Press [FILTER] button on the remote control.
(2) Push [TEMPORARY] button on the indoor unit.
Note: if [TEMPORARY] button is pushed while the
filter check lamp is not indicating, the indoor unit
will start the Automatic Operation.