– 16 –
5-3. RAS-13UK-ES3 / RAS-13UA-ES3
Note
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(
°
C)
Indoor
Outdoor
Standard 0.90 9.0 High 27/19 35/24
Cooling Overload 1.03 13.0 High 32/23 43/26
Low temperature 0.70 2.0 Low 21/15 21/15
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (
°
C)
Fan speed
(indoor)
50Hz
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
∅
1.5 x 500
l
PA150X2T-4FM1
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:12.7 mm
O.D.:6.35 mm
Cooling
Packed valve
(
∅
12.7)
Packed valve
(
∅
6.35)
0.39 m
(Connecting pipe)
∅
12.7
0.49 m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410a : 0.95 kg.
FILE NO. SVM-04017