5-1. RAS-07EKH, RAS-09EKH (Indoor Unit)
No.
1
2
3
4
5
6
7
Parts name
Fan motor (For indoor)
Thermo sensor (TA sensor)
Transformer
Microcomputer
Power relay, Common relay
Heat exchanger sensor
(TC-sensor)
Type
MMF-200-18-2C
(microporcessor)
EVN40M105UL1
TTZ-200/240-1
TMP87CH40N
G4A-1A
(microprocessor)
Specifications
Output (Rated) 18W, 2 pole, 1 phase, 220 – 240V, 50 Hz
Winding resistance (
Ω
)
(at 20°C)
Adjustable range: 17 – 30°C
400WV, 1
µ
F
Primary 200 – 240V, Secondary 15V
Coil: 12V 90mA, Rated 250V 20A
10 K
Ω
at 25 °C
Red-Black
101.6
White-Black
209.4
Runing
capacitor
for indoor fan motor
5-2. RAS-07EAH (Outdoor Unit)
5-3. RAS-09EAH (Outdoor Unit)
No.
1
2
3
4
5
6
Parts name
Compressor
Fan motor (For outdoor)
Running capacitor (For fan motor)
Running capacitor (For compressor)
Solenoid coil
Overload relay
Type
PH70T
1
-4C
UE6-21A5P
EEP2G155HQA104
SK-40CMF15UT
LB60012
J-MRA99259-9201
Specifications
Output (Rated) 500W, 2 pole, 1 phase, 220 – 240V, 50 Hz
Winding resistance (
Ω
)
(at 20°C)
Output (Rated) 18W, 6 pole, 1 phase, 220 – 240V, 50 Hz
Winding resistance (
Ω
)
(at 20°C)
400V AC, 1.5
µ
F
400VAC, 15
µ
F
AC: 200/240V
AC: 200/240V
Red-Black
4.46
White-Black
6.55
Red-Black
366.2
White-Black
368.5
No.
1
2
3
4
5
6
Parts name
Compressor
Fan motor (For outdoor)
Running capacitor (For fan motor)
Running capacitor (For compressor)
Solenoid coil
Overload relay
Type
PH940T
1
-4C
UE6-21A5P
EEP2G155HQA104
EAG40M206UF2
LB60012
J-MRA99260-9200
Specifications
Output (Rated) 750W, 2 pole, 1 phase, 220 – 240V, 50 Hz
Winding resistance (
Ω
)
(at 20°C)
Output (Rated) 18W, 6 pole, 1 phase, 220 – 240V, 50 Hz
Winding resistance (
Ω
)
(at 20°C)
400V AC, 1.5
µ
F
400V AC, 15
µ
F
AC: 200/240V
AC: 200/240V
Red-Black
4.53
White-Black
8.73
Red-Black
366.2
White-Black
368.5