When the room temperature drops below 16°C, the Dehumidifier may frost. The Defrosting cycle will
be activated during Dehumidifying Operation every 38 minutes (takes about 8 minutes) by switching
to Fan Operation, to ensure proper operation of the Unit.
Display indicates “P1” during Defrosting Operation.
Do not unplug the power cord to force abort the Defrosting Operation.
Do not unplug the power cord to force abort the Defrosting Operation.
Operating noise
Operation and Performance
Dehumidifying capacity
Dehumidifying capacity (Operation at High Fan Speed)
Operating the Dehumidifier under the conditions set out below, the dehumidifying capacity is the amount
of moisture removed per day (24 hours): High Fan Speed Operation at a room temperature of 26.7°C,
indoor humidity of 60%, with no preset humidity level, and the Louver fully open. Operating with other
settings and different Louver swing angle would diminish the dehumidifying capacity.
The correlation among room temperature,
humidity and dehumidifying capacity
Dehumidifying capacity at constant room temperature
The amount of dehumidifying increases with increasing
humidity level and vice versa. Eg. Humidity level at 60%.
When the Unit operates at the preset Humidity Level,
it stops Dehumidifying Operation and the Fan runs
at Low Speed. The amount of moisture removed
may be small in such a situation but this is not a
malfunction.
How does a dehumidifier work?
The Unit draws moist air from the
environment and cools it with evaporator.
1
2
As moist air passes through the evaporator coils,
moisture freezes and transforms into water
droplet that drips down into the Water Tank.
Warm dry Air
Evaporator Condenser
Moist Air
Compressor
Water Tank
Indoor air passes through the
evaporator coils and condenses on
the cold coil into water droplets.
Defrost cycle during operation
Rise of room temperature during operation
The Dehumidifier does not have a cooler function.
The Unit generates heat during operation that the room temperature may rise by 1°C -4°C.
The noise of the movement of the refrigerant is rather loud at start-up but it quiets down after warm-up.
When the machine is below the set humidity and the
operation mode is [Set Humidity], it will automatically
stop the dehumidification operation and switch to the
air supply mode ( air volume [low]). Although the
dehumidification volume will decrease at this time,
it is not abnormal.
Summary of Contents for RAD-Y200H
Page 1: ...0 RAD Y200H RAD Y250H RAD Y300H 家庭用 濾網安裝方法 ...
Page 2: ...如需維修請聯絡東芝服務中心 這様可能會造成短路或損壞電源線內部 ...
Page 5: ...水箱 水箱把手 水箱蓋 前面板 後面板 頂蓋 導風葉 把手 繞線柱 排水口 過濾網 腳輪 三合一 多功能 過濾網 不能正常運作 ...
Page 7: ...9 啟動此模式 ...
Page 10: ......
Page 11: ...鍵 睡眠鍵 按下此鍵可開啟 關閉睡眠模式 按住為按鍵3秒可關 開啟屏顯功能 在運轉過程操作時間掣按鍵 可設定定時關機時間 ...
Page 12: ...沾在排水口周圍水可能 會滴下 請擦掉 ...
Page 13: ...排水管規格 ...
Page 14: ...水 水 頑固的污垢要用中性清潔劑沾濕軟布 扭乾後擦拭 ...
Page 16: ......
Page 17: ...17 ...
Page 18: ...18 RAD Y200H RAD Y250H RAD Y300H 使用溫度範圍 5 32 3 15A 安裝三合一多功能過濾網後除濕性能會下降 ...
Page 30: ...Coil up the power cord when moving the Dehumidifier 12 Insert the Water Tank back ...
Page 31: ......