230
P9 ASD Installation and Operation Manual
My Function Percent Data 3
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Percent Data 3
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F920
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Percent Data 4
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Percent Data 4
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F921
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Percent Data 5
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Percent Data 5
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F922
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 1
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Frequency Data 1
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F923
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 2
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Frequency Data 2
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F924
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 3
Program
My Function
My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the
My Function Frequency Data 1
.
The analog signal is selected using the
Input Setting
.
Direct Access Number — F925
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 200.00
Units — %