ELECTRICAL ADJUSTMENTS
2-3: RF AGC
1.
2.
3.
4.
Receive the VHF HIGH (70dB).
Connect the digital voltmeter between the pin 5 of
CP602 and the pin 1 (GND) of CP602.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (02) on the remote control to
select "RF DELAY".
Press the VOL. UP/DOWN button on the remote control
until the digital voltmeter is 2.65
±
0.05V.
2-7: WHITE BALANCE
NOTE: Adjust after performing CUT OFF adjustment.
1.
2.
3.
4.
5.
6.
7.
8.
Place the set with Aging Test for more than 15 minutes.
Receive the color bar pattern.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (10) on the remote control to
select "R CUT OFF".
Using the VOL. UP/DOWN button on the remote control,
adjust the R CUT OFF.
Press the CH. UP/DOWN button on the remote control to
select the "R DRIVE", "B DRIVE", "G CUT OFF" or "B
CUT OFF".
Using the VOL. UP/DOWN button on the remote control,
adjust the R DRIVE, B DRIVE, G CUT OFF or B CUT
OFF.
Perform the above adjustments 6 and 7 until the white
color is looked like a white.
2-8: FOCUS
1.
2.
3.
Receive the monoscope pattern.
Turn the Focus Volume fully counterclockwise once.
Adjust the Focus Volume until picture is distinct.
2-9: HORIZONTAL PHASE
1.
2.
3.
4.
Receive the monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (05) on the remote control to
select "H PHASE".
Press the VOL. UP/DOWN button on the remote
control until the SHIFT quantity of the OVER SCAN on
right and left becomes minimum.
(TV SECTION)
2-4: CONSTANT VOLTAGE
1.
2.
3.
4.
5.
6.
Input DC12V to DC Jack and turn the Power ON.
Connect the digital voltmeter to the TP401.
Set condition is AV MODE without signal.
Adjust the VR501 until the DC voltage is 101
±
0.5V.
Input AC120V to AC cord and remove the DC Jack
cord. Check if the Power is ON before doing the above
procedure.
Adjust the VR502 until the DC voltage is 102
±
0.5V.
2-10: VERTICAL SIZE
NOTE: Adjust after performing adjustments in section 2-9.
1.
2.
3.
4.
5.
Receive the cross hatch signal from the Pattern
Generator.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (06) on the remote control to
select "V SIZE".
Press the VOL. UP/DOWN button on the remote
control until the rectangle on the center of the screen
becomes square.
Receive a broadcast and check if the picture is normal.
2-5: OSD HORIZONTAL
1.
2.
Activate the adjustment mode display of Fig. 1-1.
Press the VOL. UP/DOWN button on the remote
control until the difference of A and B becomes
minimum. (Refer to Fig. 2-2)
B
A
TV
00 OSD 15
Fig. 2-2
1.
2.
3.
4.
5.
Adjust the unit to the following settings.
R CUT OFF=128, G CUT OFF=128, B CUT OFF=128,
R DRIVE=64, B DRIVE=64, BRIGHTNESS=128,
CONTRAST=96
Place the set with Aging Test for more than 15 minutes.
Set condition is AV MODE without signal.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (01) on the remote control to
select "CUT OFF".
Adjust the Screen Volume until a dim raster is obtained.
2-6: CUT OFF