The unit will now have the correct DATA for the new MEMORY IC.
NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE:
Table 1
1.
2.
Fig. 1
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
ADDRESS and DATA should appear as FIG 1.
INIT 00 83
0010
0003
POWER ON
PLAY/REC
ADDRESS
DATA
Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 5 seconds before Power On.
ADDRESS
DATA
00
88
01
0A
02
82
03
43
04
42
05
23
06
34
07
6F
08
51
09
18
ADDRESS
DATA
0A
10
0B
9C
0C
99
0D
00
0E
00
0F
11
10
8C
11
68
12
5C
13
ADDRESS
DATA
14
00
15
00
16
30
17
05
18
05
19
00
1A
A9
1B
05
1C
05
1D
39
ADDRESS
DATA
1E
8D
1F
00
20
00
21
00
22
00
23
00
24
00
25
00
26
00
27
00
53
ADDRESS
DATA
28
00
29
00