– 11 –
21-EN
22-EN
▼
Cyclic swing (Recommended for cooling)
All four louvers swing at different times like waves.
(3)
(2)
(1)
(1)
(4)
(2)
(3)
(2)
(3)
(4)
(1)
(4)
(3)
(2)
(1)
(4)
◆
Setting the louver lock
1
Push and hold the
button (right side
of the button) for at least 4 seconds while
running is stopped.
blinks.
•
When no unit number is displayed, all units are
selected.
2
Push
the
button (left side of the
button) to select a unit.
The unit number changes each time the button is
pushed.
Unit No.
1-1
Unit No.
1-2
Unit No.
1-3
Unit No.
1-4
The fan of the selected unit runs, and the louver
swings.
3
Push the “TEMP.
” buttons to
display the number of the louver to
fi
x its
direction.
The selected louver swings.
4
Push
the
buttons to select the
direction of the louver you do not want to
swing.
(1)
0001
(2)
0002
(3)
0003
(5)
0005
(4)
0004
*
If (4) or (5) is selected, condensation may occur
during cooling.
03
01
02
04
Refrigerant
pipe
Drain pipe
Electrical control box
5
Push
the button to con
fi
rm the setting.
When the setting is con
fi
rmed, the mark lights
up.
(To set the louver lock of another unit, repeat from
Step 2. To set another louver lock of the same
unit, repeat from Step 3.)
6
Push
the button to
fi
nish the setting.
0001 - 0005
(Louver position
code)
Louver No.
*
F1 appears in the CODE No. section on the
remote control. This indicates that the louver 01
shown in the following
fi
gure is selected.
NOTE
Even in louver lock mode, the louver temporarily
moves in the following cases:
•
When the air conditioner is stopped
•
When heating starts
•
When defrosting
•
When thermostat
◆
Releasing the louver lock
Set “0000” in Step 4 of “Setting the louver lock”.
The mark disappears.
*
Steps 1 - 3 and 5, 6 of “Setting
the louver lock” also apply to
releasing the lock.
◆
Adjusting the horizontal direction
1
Push and hold the and “TEMP.
”
buttons for at least 4 seconds while
running is stopped.
blinks.
“01” appears in CODE No.
2
Push
the
button (left side of the
button) to select a unit
The unit number changes each time the button is
pushed.
Unit No.
1-1
Unit No.
1-2
Unit No.
1-3
Unit No.
1-4
No display
The fan of the selected unit runs, and the louver
swings.
3
Push the “TEMP.
” buttons to
change the CODE No. to “45”.
4
Push the “TIME
” buttons to select a
direction.
Direction SET
DATA
Direction setting
“0000”
Smudging reduction position
(reduces ceiling smudging)
“0002”
Cold draft preventive position
(Prevent cold draft)
[Factory default]
5
Push
the button to check the settings.
The indicator stops blinking and stays lit, and the
settings are con
fi
rmed.
6
Push button to
fi
nish the setting.
*
If the cold draft position is selected, the ceiling
smudging reduction effect will be reduced.
0000
SET DATA
1117907101 EN FR.indb 11
1117907101 EN FR.indb 11
3/21/16 11:44 AM
3/21/16 11:44 AM