background image

– 11 –

3

Push the 

 button to confirm the 

direction of the selected louver.

Each time the button is pushed, the indication 
changes as follows:

* When cooling or drying, (4) and (5) are not 

displayed.

Setting the swing pattern

1

Push and hold the 

 

FIX for at least 4 

seconds while the operation is stopped.

 blinks.

2

Push the 

 button (left side of the button) 

to select a unit.

The unit number changes each time the button is 
pushed.

The fan of the selected unit runs, and the louver 
swings.

3

Push the 

 

 buttons to select a swing 

type.

REQUIREMENT

Do not set “0000”.
(The louver may be damaged.)

4

Push the 

 button.

5

Push the 

 button to finish the setting.

Standard swing

All four louvers swing simultaneously at the same 
angle.

Dual swing (Recommended for heating)

• Adjoining louvers alternately point horizontally and 

downward to heat the room evenly.

• Air blown downward reaches the floor, and air blown 

horizontally is spread to circulate heat.

Swing code

Movement pattern

0001

Standard swing 

(factory default)

0002

Dual swing

0003

Cyclic swing

SWING/FIX

(1)

(2)

(3)

(4)

(7)

(6)

(5)

SWING/FIX

UNIT  LOUVER

No 

display

Unit No. 

1-1

Unit No. 

1-2

Unit No. 

1-3

Unit No. 

1-4

Swing code

Swing

Horizontal

Downward

Downward

Horizontal

Downward

Downward

Horizontal

Horizontal

Cyclic swing (Recommended for cooling)

All four louvers swing at different times like waves.

Setting the louver lock

1

Push and hold the 

 

button (right side of 

the button) for at least 4 seconds while 
running is stopped.

 blinks.

• When no unit number is displayed, all units are 

selected.

2

Push the 

 button (left side of the button) 

to select a unit.

The unit number changes each time the button is 
pushed.

The fan of the selected unit runs, and the louver 
swings.

3

Push the “TEMP. 

 

” buttons to 

display the number of the louver to fix its 
direction.

The selected louver swings.

4

Push the 

 

 buttons to select the 

direction of the louver you do not want to 
swing.

* If (4) or (5) is selected, condensation may occur 

during cooling.

5

Push the 

 button to confirm the setting.

When the setting is confirmed, the 

 mark lights 

up.
(To set the louver lock of another unit, repeat from 
Step 2. To set another louver lock of the same unit, 
repeat from Step 3.)

(3)

(2)

(1)

(1)

(4)

(2)

(3)

(2)

(3)

(4)

(1)

(4)

(3)

(2)

(1)

(4)

UNIT  LOUVER

UNIT  LOUVER

Unit No. 

1-1

Unit No. 

1-2

Unit No. 

1-3

Unit No. 

1-4

(1)

0001

(2)

0002

(3)

0003

(5)

0005

(4)

0004

03

01

02

04

Refrigerant 

pipe

Drain pipe

Electrical control box

21-EN

22-EN

+00EH99943901_00Ta.book  Page 11  Thursday, May 23, 2013  7:17 PM

Summary of Contents for MMY-MAP0724FT6UT

Page 1: ...η προσβάσιμο από το γενικό κοινό Недоступен для посторонних Genel erişime açık değildir AIR CONDITIONER MULTI TYPE Outdoor Unit Model name Heat Recovery Model MMY MAP0724FT9UL MMY MAP0964FT9UL MMY MAP1204FT9UL MMY MAP0724FT6UL MMY MAP0964FT6UL MMY MAP1204FT6UL Owner s Manual For OUTDOOR USE only Pour une UTILISATION EN EXTÉRIEUR uniquement Manuel du propriétaire 18 Français Owner s Manual 1 Englis...

Page 2: ...ot assume any liability for the damage caused by not observing the description of this manual WARNING General Carefully read Owner s Manual before starting the air conditioner There are many important things to keep in mind for daily operation Ask for installation to be performed by the dealer or a professional Only a qualified installer is able to install an air conditioner If a non qualified per...

Page 3: ... set the circuit breaker to the OFF position and contact a qualified service person to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the OFF position and contact a qualified installer or a qualified service person to refit the un...

Page 4: ...Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down Stacking height 12 cartons can be stacked in this case This side up Do not step Handle with care Model type Model Name 4 way cassette type MMU AP H UL Compact 4 way cassette type MMU AP MH UL Ceiling type MMC AP H UL High wall type MMK AP H UL For details on these models read the owner s manuals that come with the i...

Page 5: ...rge air directions Ceiling type Medium static ducted type High static ducted type Slim ducted type Air filter Filters out dust Inside the air intake Discharge louver Controls discharge air directions Air intake Air in the room is taken in through here Ground screw Equipped on the electrical control box Air filter Filters out dust Inside the air intake locally procured Air discharge The air dischar...

Page 6: ...rost cycle is initiated While this indication is displayed the indoor fan stops 13 No function display Displayed when the function requested is not available on that model 14 Fan speed display The selected fan speed mode is displayed Only HIGH is displayed for the high static ducted type 15 Louver Number display Louvers can be controlled individually Displays which louver is being set exapmle 01 0...

Page 7: ... unit is on Although it flashes when operating the protection device or an error occurs 9 button When the button is pushed the operation starts and it stops by pushing the button again When the operation has stopped the operation lamp and all the displays disappear 10 button Selects desired operation mode 11 button Selects a unit number left and louver number right UNIT Selects an indoor unit when...

Page 8: ...ctable in the Fan mode The fan speed selecting function is not available for the high static ducted type Only HIGH is displayed 4 Select the set point temperature by pushing the TEMP or TEMP buttons Stop Push button The operation lamp goes off and the operation stops In the Cool Dry or Auto cooling mode the fan runs for 10 minutes or more for self cleaning SET TIME TIMER SET TEST FILTER RESET TEMP...

Page 9: ...ing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Places where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations such as the following Areas with large am...

Page 10: ...he machines Protective device High pressure switch The high pressure switch stops the air conditioner automatically when excessive load is applied to the air conditioner If the protective device activates the unit s running stops and the operation lamp blinks When the protective device activates the indicator and the check code are displayed on the remote control The protective device may activate...

Page 11: ...eration the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Unit select When two or more indoor units are controlled with one remote control the louver direction can be set for each indoor unit by selecting them individually To set louver direction individually pus...

Page 12: ... 3 Unit No 1 4 Swing code Swing Horizontal Downward Downward Horizontal Downward Downward Horizontal Horizontal Cyclic swing Recommended for cooling All four louvers swing at different times like waves Setting the louver lock 1 Push and hold the button right side of the button for at least 4 seconds while running is stopped blinks When no unit number is displayed all units are selected 2 Push the ...

Page 13: ...e louver points upward The swing indication appears on the remote control even in pre heating mode but the actual swing starts only after pre heating is complete 2 way and 3 way air discharge The air discharge can be changed to the 2 way or 3 way type to suit the room shape and style For details contact the dealer where you purchased the air conditioner Ceiling type Vertical adjustment The louver ...

Page 14: ...ver Exposing yourself to blowing air directly for a long time is bad for your health Check periodically Close Do not cool down too much Air conditioner operating conditions For proper performance operate the air conditioner under the following temperature conditions When the outside temperature exceeds 70 F 21 C it cannot operate heating When the outside temperature is below 14 F 10 C it cannot op...

Page 15: ...tdoor heat exchanger from Outside Clean Outdoor heat exchanger from Inside 2 Blow Air Over Electric Parts 2 Check Electric Connection Tightening 2 Clean Fan Wheel 2 Check Fan Tightening 2 Clean Drain Pans 2 1 1 1 1 1 1 1 1 Increase frequency in dusty zones 2 Maintenance to be carried out by qualified service personal 4 way cassette type REQUIREMENT Clean the heat exchanger with pressurized water I...

Page 16: ...he louver sagging down the center downward 1 Insert latch Air intake S l i d e Hook Air filter Handle Handle Hook Air intake Latch Air filter CAUTION Do not start the air conditioner while leaving the panel and air filter removed Cleaning Unit Grille and Frame To clean the grille and the frame wipe the outside with a soft dry cloth If necessary a mild liquid detergent can be applied and wiped off ...

Page 17: ... If is displayed on the remote control replace the air filter 1 Push the button to stop the operation then turn off the circuit breaker 2 Replace the new air filter locally procured 1 Remove the cover plate Remove the cover plate with 2 screws 2 Insert in the louver sagging down the center downward 1 Insert 4 1 3 Cover plate fixing screws Cover plate 2 Pull out the filter rack and set the air filt...

Page 18: ... intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to LOW MED and is the operation mode set to FAN Is the setup temp the appropriate temperature Is outdoor temperature out of operation temperature range CAUTION If any of the following conditio...

Page 19: ...EH99943901 00EH99943901_00Ta book Page 35 Thursday May 23 2013 7 17 PM ...