DN
Item
At shipment
Filter display delay timer
0000: None
0001: 150H
Depending on model
0002: 2500H
0003: 5000H
type
0004: 10000H
d
r
a
d
n
a
t
S
:
0
0
0
0
d
r
a
d
n
a
t
S
:
0
0
0
0
r
e
t
li
f
f
o
e
t
a
t
s
y
t
r
i
D
0001: High degree of dirt (Half of standard time)
Central control address
0001: No.1 unit to 0064: No.64 unit … TCC-LINK
00Un/0099: Unfixed *1
0001: No.1 unit to 0128: No.128 unit … TU2C-LINK
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
Specific indoor unit
0000: No priority
0001: Priority
0000: No priority
priority
Heating temp. shift
0000: 0 °C
0001: +1 °C
Depending on model
0002: +2 °C
to
0010: +10 °C
type
(Up to +6 recommended)
Demand control
0000: Demand input
0002: Card input setup.3
0004: Card input setup.4
0005: Fire alarm input
(Normal close)
0007: Card input setup.5
0009: Card input setup.2
0001: O2 sensor input
0003: Fire alarm input
(Normal open)
0006: Notice cord (202)
0008: Card input setup.1
0000: Demand input
(CN73 / CN4)
d
e
d
i
v
o
r
p
t
o
N
:
1
0
0
0
d
e
d
i
v
o
r
P
:
0
0
0
0
]
O
T
U
A
[
f
o
e
c
n
e
t
s
i
x
E
d
e
d
i
v
o
r
p
t
o
N
:
1
0
0
0
e
d
o
m
(Automatic selection from connected outdoor unit)
p
m
u
p
t
a
e
H
:
0
0
0
0
p
m
u
p
t
a
e
H
:
0
0
0
0
y
l
n
o
g
n
il
o
o
C
0001: Cooling only (No display of [AUTO] [HEAT])
Type
Refer to
Type DN code "10" list
Depending on model
type
Indoor unit capacity
0000: Unfixed
0001 to 0034
According to capacity
Refer to Indoor Unit Capacity DN code "11"
ޓ
list
type
Line address
0001: No.1 unit to 0064: No.30 unit … TCC-LINK
00Un/0099: Unfixed *1
0001: No.1 unit to 0128: No.128 unit … TU2C-LINK
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
Indoor unit address
0001: No.1 unit to 0064: No.64 unit … TCC-LINK
00Un/0099: Unfixed *1
0001: No.1 unit to 0128: No.128 unit … TU2C-LINK
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
Group address
0000: Individual 0001: Header unit of group
00Un/0099: Unfixed *1
0002: Follower unit of group
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
Louver type
0000: No louver
0001: Swing only
Depending on model
(Air direction adjustment)
0004: (4-way Air Discharge Cassette type, etc.)
type
Temp difference of
0000: 0 °C
to
0010: 10 °C (Ts ± 5°C)
0003: 3 °C
)
C
°
5
.
1
±
s
T
(
n
o
i
t
c
e
l
e
s
e
d
o
m
]
O
T
U
A
[
COOL
㸢
HEAT,
HEAT
㸢
COOL
Ts:Remote controller setup temp.
Automatic restart of
0000: None
0001: Restart
0000: None
power failure
Selection of option/Trouble
0000: Filter input
0001: Alarm input
0002: None
input
(TCB-PCUC2E: CN3)
0002: None
(Air washer, etc.)
HA terminal (CN61)
0000: Usual
0002: Fire alarm input
(arbiter contact)
0004: Notice cord (201)
0000: Usual
0001: Card input setup.1 (3)
0003: Card input setup.2 (4)
0005: Card input setup.5
t
c
e
l
e
s
(HA terminal)
31
Ventilating fan control
0000: Unavailable
0001: Available
0000: Unavailable
32
TA sensor selection
0000: Body TA sensor
0001:
Remote controller sensor
0000: Body TA sensor
12
13
19
28
2A
03
14
2E
Description
01
02
1E
04
06
0b
0d
0F
10
11
Indoor unit function Code No. (DN Code) table
(includes functions needed to perform applied control on site)
- 35 -
Summary of Contents for MMK- UP0301HP Series