5
CUTTING A HOLE AND MOUNTING INSTALLATION
PLATE
Cutting a hole
In case of installing the refrigerant pipes from the
rear:
1. Decide the hole position for piping at
4.3″ (110 mm) from the arrow mark ( ) on
the installation plate and drill a hole at a
slight downward slant toward outdoor side.
1. Securely fit the installation plate onto the
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2. To mount the installation plate on a
concrete wall with anchor bolts, utilize
the anchor bolt holes as illustrated in the
above figure.
3. Install the installation plate horizontally in
the wall.
0.2″ (5 mm) dia. hole
Anchor bolt
Projection
0.6″ (15 mm) or less
Clip anchor
(local parts)
Mounting screw
Ø5/32″ (4 mm) × 1.0″ (25 mm)
NOTE
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe
hole brim ring sold separately.
• In case of block, brick, concrete or similar type
walls, make 0.2″ (5 mm) dia. holes in the wall.
• Insert clip anchors for appropriate mounting
screws.
When installing the installation plate with a
mounting screw, do not use the anchor bolt
hole. Otherwise the unit may fall down and
result in personal injury and property damage.
Mounting the installation plate
When the installation plate is
directly mounted on the wall
CAUTION
NO
GOOD
NO
GOOD
OK
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit
falls.
NOTE
• Secure four corners and lower parts of the
installation plate with 6 mounting screws to
install it.
Anchor bolt
holes
Pipe
hole
Pipe hole
Indoor unit
Installation
plate
Thread
Weight
Mounting screw
Mounting screw
Mounting
screw
Mounting
screw
2.2″ (57 mm)
2″ (50 mm)
4.8″
(123 mm)
2.4″
(61 mm)
0.9″
(23 mm)
4.3″
(110 mm)
Unit outline
2″ (50 mm)
4.3″ (110 mm)
Dia 3.1″ (180 mm)
170
8
5
Hook
Hook
Hook
Hook
- 88 -