background image

MBS (Wallmount) Installation - 64523-009

2

GENERAL SAFETY 

GENERAL SAFETY INSTRUCTIONS

DO NOT attempt to install, operate, maintain or dispose of this equipment until you have read and understood all of the 

product safety information and directions that are contained in this manual.

Safety Alert Symbol
 

The Safety Alert Symbol indicates that a potential personal injury hazard exists. The

              symbol is comprised of an equilateral triangle enclosing an exclamation mark.

Signal Words

Listed below are the signal words that are used throughout this manual followed by their descriptions and associated 

symbols. When the words DANGER, WARNING, CAUTION and NOTICE are used in this manual they will be followed by 

important safety information that must be carefully adhered to.
Warnings in this manual may appear in any of the following ways:

DANGER 

Danger warning

 ─ The word DANGER in capital letters preceded by the safety alert symbol indicates 

that an imminently hazardous situation exists, and if not avoided will result in loss of life or serious injury 

to personnel.

WARNING  

Warning warning

 ─ The word WARNING in capital letters preceded by the safety alert symbol indicates 

that a potentially hazardous situation exists, and if not avoided may result in loss of life or serious injury 

to personnel.

CAUTION  

Caution warning

 ─ The word CAUTION in capital letters preceded by the safety alert symbol indicates 

that a potentially hazardous situation exists, and if not avoided may result in minor or moderate injury.

NOTICE

 

Notice warning

 ─ The word NOTICE in capital letters without the safety alert symbol indicates a poten

-

tially hazardous situation exists, and if not avoided may result in equipment and property damage.

Other warning symbols may appear along with the Danger and Warning symbol and are used to specify special hazards. 

These warnings describe particular areas where special care and/or procedures are required in order to prevent serious 

injury and possible death.

1.  Electrical warning

 ─ The electrical warning symbol is a lighting bolt enclosed in a triangle. The Electrical warn

-

ing symbol is used to indicate high voltage locations and conditions that may cause serious injury or death if 

the proper precautions are not observed.

2.  Explosion warning 

─ The explosion warning symbol is an explosion image enclosed in a triangle. The Explo

-

sion warning symbol is used to indicate locations and conditions where molten exploding parts that may 

cause serious injury or death if the proper precautions are not observed.

EQUIPMENT WARNING LABELS
DO NOT 

attempt to install, operate, maintain or dispose of this equipment until you have read and understood all of the 

product warnings and user directions that are contained in this instruction manual.
Shown below are examples of warning labels that may be found attached to the equipment. DO NOT remove or cover 

any of the labels. If the labels are damaged or if additional labels are required, contact your TOSHIBA representative for 

additional labels.
The following are examples of the warning labels that may be found on the equipment. The labels are there to provide 

useful information or to indicate an imminently hazardous situation that may result in serious injury, severe property and 

equipment damage, or death if the instructions are not followed.

DANGER

AC VOLTAGE

This MBS receives power from more
than one source. Disconnect all AC
sources before performing any service
or testing inside this unit

MATERIAL - VINYL OR POLYESTER
TEMPERATURE - MINUS 20 TO 100 deg. C
ADHESIVE - V23 OR EQUIV.
MUST RESIST OIL SOLVENTS
ALL MATERIALS USED MUST
BE UL RECOGNIZED
WARNING AREA BACKGROUND COLOR: ANSI DANGER RED
WARNING AREA TEXT COLOR: ANSI WHITE
TEXT AREA BACKGROUND COLOR: ANSI WHITE
TEXT AREA TEXT COLOR: ANSI BLACK
CORNER RADIUS: VENDOR STANDARD

0.00

WARNING AREA

TEXT AREA

0.00

3.00

1.50

64819

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF TOSHIBA INTERNATIONAL
CORPORATION AND SHALL NOT BE REPRODUCED, USED, OR DISCLOSED
TO OTHERS UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED.

TITLE:

SCALE:

DRAWING NO.:

ECN

DATE

BY

DRAWN:

CHECKED:

APPROVED:

DANGER LABEL
MULTIPLE SOURCES

64819

FULL

WLM 3-10-11

REV:

0

13131 WEST LITTLE YORK ROAD, HOUSTON, TX 77041 U.S.A.

ZIR 3-10-11

WLM 3-9-11

PN 64821

Remove conduit plate prior to drilling. Metal

chips may fall into breaker orifice and cause

a short circuit.

CAUTION

TEXT AREA

1.50”

4.00"

Risk of electrical shock.

MATERIAL - VINYL OR POLYESTER
TEMPERATURE - MINUS 20 TO 100 deg. C
ADHESIVE - V23 OR EQUIV.
MUST RESIST OIL SOLVENTS
ALL MATERIALS USED MUST
BE UL RECOGNIZED

CAUTION AREA BACKGROUND COLOR: ANSI CAUTION YELLOW
CAUTION AREA TEXT COLOR: ANSI BLACK
TEXT AREA BACKGROUND COLOR: ANSI WHITE
TEXT AREA TEXT COLOR: ANSI BLACK
CORNER RADIUS: VENDOR STANDARD

C A U T I O N

AREA

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF TOSHIBA INTERNATIONAL
CORPORATION AND SHALL NOT BE REPRODUCED, USED, OR DISCLOSED
TO OTHERS UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED.

TITLE:

SCALE:

DRAWING NO.:

ECN

DATE

BY

DRAWN:

CHECKED:

APPROVED:

CAUTION LABEL
MBS

64821

1=1

WLM 9-3-11

REV:

0

13131 WEST LITTLE YORK ROAD, HOUSTON, TX 77041 U.S.A.

WLM 3-10-11

ZIR 3-10-11

 

 

 

 

 

 

Summary of Contents for MBSWH-10K-F3-KK

Page 1: ...80 208 120V 300A 65 000 MBSWH 10K F3 KK 36 x 12 8 x 48 1 385 100 208 120V 400A 65 000 MBSWH 150 S3 KK 30 1 x 10 8 x 42 1 130 15 480V 40A 35 000 MBSWH 250 S3 KK 30 1 x 10 8 x 42 1 130 25 480V 40A 35 000 MBSWH 300 S3 KK 30 1 x 10 8 x 42 1 130 30 480V 50A 35 000 MBSWH 500 S3 KK 30 1 x 10 8 x 42 1 130 50 480V 100A 35 000 MBSWH 800 S3 KK 30 1 x 10 8 x 42 1 130 80 480V 125A 35 000 MBSWH 10K S3 KK 30 1 x...

Page 2: ...warn ing symbol is used to indicate high voltage locations and conditions that may cause serious injury or death if the proper precautions are not observed 2 Explosion warning The explosion warning symbol is an explosion image enclosed in a triangle The Explo sion warning symbol is used to indicate locations and conditions where molten exploding parts that may cause serious injury or death if the ...

Page 3: ...DE 8 TORQUE SPEC 119 FT LB ENSURE PROPER PHASING LINE IN USE COPPER CONDUCTORS ONLY REFER TO INSTRUCTION MANUAL FOR WIRE SIZE A B C 1 2 BOLT SAE GRADE 8 TORQUE SPEC 119 FT LB ENSURE PROPER PHASING LOAD IN USE COPPER CONDUCTORS ONLY REFER TO INSTRUCTION MANUAL FOR WIRE SIZE A B C 1 2 BOLT SAE GRADE 8 TORQUE SPEC 119 FT LB ENSURE PROPER PHASING UPS IN USE COPPER CONDUCTORS ONLY REFER TO INSTRUCTION ...

Page 4: ...alling this hasp are given in Appendix A POWER CABLING INSTRUCTIONS The MBS Circuit Breakers are equipped with terminal bus strips The terminal bus strips are pre drilled with standard 2 hole NEMA patterns to facilitate installation of power cables Medium Case 3 8 in bolt holes on 1 75 in centers Large Case 1 2 in bolt holes on 1 75 in centers Use of NEMA two hole cable terminations is recommended...

Page 5: ... Grey CLND 3 12 134 Long Barrel 1 2 in 1 75 in 3 White CLND 2 12 134 CSWD 2 12 134 Long Barrel Short Barrel 1 2 in 1 75 in 2 Brown CLND 1 12 134 Long Barrel 1 2 in 1 75 in 1 Green CLND 1 0 12 134 CSWD 1 0 12 134 Long Barrel Short Barrel 1 2 in 1 75 in 1 0 Pink CLND 2 0 12 134 CSWD 2 0 12 134 Long Barrel Short Barrel 1 2 in 1 75 in 2 0 Black CLND 3 0 12 134 Long Barrel 1 2 in 1 75 in 3 0 Orange CLN...

Page 6: ...the power cables as indicated below Verify phasing is correct before applying power LINE IN CB1 CB2 CB3 UPS IN LOAD IN UPS OUT Figure 1 MBS Power Cabling Connections Phase A B C Phase A B C Phase A B C Phase A B C NEUTRAL GND N N GND GND N N GND GND ...

Page 7: ...r SKRU UPS Bypass Enable TB End User Supplied Wiring 16 18 gage twisted pair MBS TB 1 1 2 V SKRU SKRU L MBSWH xxx F3 KS 120VAC MBSWH xxx S3 KS 24VDC Table 5 SKRU Point to Point Wiring From UPS Model Terminal Board To MBSWH Terminal Board 4200FA TB2 11 MBSWH TB1 1 4200FA TB2 12 MBSWH TB1 2 4300 TB3 1 MBSWH TB1 1 4300 TB3 2 MBSWH TB1 2 4400 TB3 1 MBSWH TB1 1 4400 TB3 2 MBSWH TB1 2 G8000 TB1 10 MBSWH...

Page 8: ...S Input Breaker 2 Turn UPS ON Verify UPS is in Bypass 3 Turn ON all UPS Battery DC breakers 4 Unlock CB3 5 Close CB3 UPS Output Breaker 6 Remove the key from CB3 and insert it in CB2 7 Open CB2 Maintenance Bypass Breaker 8 Lock CB2 9 Return UPS to Online Mode 3 Breaker MBS with SKRU Solenoid Key Release Unit Place MBS in Maintenance Bypass Mode 1 Transfer the UPS to static bypass Verify UPS is in ...

Page 9: ...MBS Wallmount Installation 64523 009 9 PARAMETERS 15 160kVA UNIT WEIGHT LBS KGS 130 58 9 VENTILATION REQTS NONE FINISH GRAY Figure 3 Dimensional Drawing for 0 200A MBSWH ...

Page 10: ...MBS Wallmount Installation 64523 009 10 PARAMETERS 80 500kVA UNIT WEIGHT LBS KGS 280 127 0 VENTILATION REQTS NONE FINISH GRAY Figure 4 Dimensional Drawing for 300A MBSWH ...

Page 11: ...rections until the 0 5 mm join separates 2 use the factory supplied hardware to mount the outer loop of the hasp on the MBS door The two mounting holed for the screws is located just aoe the door latch 3 Use the factory supplied hardware to mount the inner tongue of the hasp on the inner edge of the door frame The mounting holes are located just above the goor latch 4 After mounting both parts of ...

Page 12: ......

Page 13: ...POWER ELECTRONICS DIVISION 13131 West Little York Road Houston Texas 77041 9990 Tel 713 466 0277 Fax 713 466 8773 US 855 803 7087 Canada 800 872 2192 https www toshiba com tic industrial uninterruptible power systems Printed in the U S A ...

Reviews: