INSTALLATION AND SETTINGS OF e-BRIDGE ID GATE
2 - 4
[E] LDAP server setting (08-1927)
The service technician sets the attribute name of the LDAP server authentication ID which has been
confirmed in procedure [A] on the equipment. Check the attribute name confirmed in procedure [A].
<Procedure>
1) Turn the power of the equipment ON while pressing the digital keys [0] and [8] simultaneously.
2) Key in “1927”, and then press the [START] button.
3) Enter the attribute name confirmed in procedure [A] using the buttons on the touch panel.
“eBMUserCard” is set by default.
4) Confirm if the entered content is correct, and then press the [ENTER] button on the touch panel.
5) Shut down the equipment.
[F] Card authentication setting
The user accesses TopAccess to enable the card authentication.
08-1927
Sets the attribute name of authentication ID on the LDAP server.
<Default: eBMUserCard>
Reference:
Setting procedure in TopAccess followed by the user
(To enable the card authentication, refer to the co-packed
Operator’s Manual
. For the detailed
procedure in TopAccess, refer to the
TopAccess Guide
.)
1) Access the equipment with the e-BRIDGE ID Gate installed from the web browser.
2) Click the User Management tab and the Authentication menu.
3) Enter the administrator password and click "Login".
4) Select “Enable” of “Card Authentication” in “User Management Setting”.
5) Log out of TopAccess.
Summary of Contents for KP-2004
Page 1: ...SERVICE MANUAL e BRIDGE ID Gate KP 2004 File No SME060032A0 R061121D2600 TTEC Ver01_2007 04 ...
Page 4: ......
Page 6: ...KP 2004 February 2007 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 2 ...
Page 8: ...KP 2004 February 2007 TOSHIBA TEC CORPORATION All rights reserved GENERAL DESCRIPTION 1 2 ...
Page 19: ......
Page 20: ......