HX7+ ASD Installation and Operation Manual
111
RX2 Speed Reference #1
Program
Frequency Setting
Speed Reference Setpoints
RX2
This parameter is used to set the gain and bias of the
RX2
input terminal when
the
RX2
terminal is used as the control input while operating in the
Speed
Control
mode or the
Torque Control
mode.
RX2 Input Speed Control Setup
Perform the following setup to allow the system to receive
Speed
control input
at the
RX2
input terminal:
•
Program
Fundamentals
Standard Mode Selection
Frequency
Mode #1
RX2
.
•
Program
Fundamentals
Standard Mode Selection
Command
Mode
Use Terminal Board
.
•
Set
RX2 Speed Reference #1
) — the input signal level that
represents
RX2 Speed Frequency #1
.
•
Set
RX2 Speed Frequency #1
(
•
Set
RX2 Speed Reference #2
) — the input signal level that
represents
RX2 Speed Frequency #2.
•
Set
RX2 Speed Frequency #2
(
•
Provide a
Run
command (
F
and/or
R
).
Once set, as the
RX2
input changes, the output frequency of the ASD will vary
in accordance with the above settings.
This parameter sets
RX2 Speed Reference #1
and is the input signal level that
is associated with the setting of
RX2 Speed Frequency #1
while operating in
the
Speed Control
mode.
RX2 Input Torque Control Setup
Perform the following setup to allow the system to receive
Torque
control input
at the
RX2
input terminal:
•
Program
Fundamentals
Standard Mode Selection
Frequency
Mode #1
RX2
.
•
Program
Fundamentals
Standard Mode Selection
Command
Mode
Use Terminal Board
.
•
Set
RX2 Speed Reference #1
) — the input signal level that
represents
RX2 Torque Reference Setpoint #1
.
•
Set
RX2 Torque Reference Setpoint #1
•
Set
RX2 Speed Reference #2
) — the input signal level that
represents
RX2 Torque Reference Setpoint #2.
•
Set
RX2 Torque Reference Setpoint #2
•
Provide a
Run
command (
F
and/or
R
).
Once set, as the
RX2
input changes, the output torque of the ASD will vary in
accordance with the above settings.
This parameter sets
RX2 Speed Reference #1
and is the input signal level that
is associated with the setting of
RX2 Torque Reference Setpoint #1
while
operating in the
Torque Control
mode.
Direct Access Number — F222
Parameter Type —
Numerical
Factory Default —
00.0
Changeable During Run —
Yes
Minimum — -100.0
Maximum — 100.0
Units — %
Frequency Settings
Note:
The speed control response
may be further trimmed by
adjusting the Bias and
Gain settings.
Torque Settings
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...