3
© 2016-2020 Toshiba Tec Corporation All rights reserved
GD-1370
DIALING/COMMUNICATION CONTROL
3 - 19
- Communication end procedure
This procedure is to terminate the communication. The transmission rate is 1,200 bps.
Transmitter
Signal name
Abbreviation
Function
Remarks
Sh signal
Sh
Short training
Sh
signal
Sh
ALT signal
ALT
-
E sequence
E
-
End of procedure signal
PPS-EOP
The transmission of one page
is completed.
Flag
flags
Maintains the
synchronization.
7E (H)
Disconnection signal
DCN
Informs to disconnect the line.
Receiver
Signal name
Abbreviation
Function
Remarks
Sh signal
Sh
Short training
Sh
signal
Sh
ALT signal
ALT
-
E sequence
E
-
Flag
flags
Maintains the
synchronization.
7E (H)
Message confirmation
MCF
Indicates that the image
signal is received normally,
and the receiver is ready to
receive the next page.