36
Register
Function / Title
Bank
Mask
Adjustment Range
Multiplier
60
“OUT” CONTACTS HOLD
TIME
0 / 1
00FF
0001
∼
0064 (1
∼
100)
1
61
LOW SPEED SIGNAL
OUTPUT FREQ
0 / 1
FFFF
0
∼
Fmax
0.01
62
ACC/DEC COMPLETE
DETECT BAND
0 / 1
FFFF
0
∼
Fmax
0.01
63
SPEED REACH MAXIMUM
FREQUENCY
0 / 1
FFFF
0
∼
Fmax
0.01
64
SPEED REACH MINIMUM
FREQUENCY
0 / 1
FFFF
0
∼
Fmax
0.01
65
COMMERCIAL POWER/INV
SWITCHING OUTPUT
0 / 1
00C0
0000: OFF
(0)
0040: Auto switch on trip
(1)
0080: At
COMMERCIAL POWER/INV
SWITCH FREQ
(2)
00C0: Both (1) and (2)
(3)
66 2,
3
COMMERCIAL
POWER/INV
SWITCH FREQ
0 / 1
FFFF
0
∼
Fmax
0.01
67
“FP” OUTPUT TERMINAL
PULSE FREQUENCY
0 / 1
0003
0000: 48f
(0)
0001: 96f
(1)
0002: 360f
(2)
68
RR INPUT SPECIAL
FUNCTION SELECT
0 / 1
00E0
0000: Standard
(0)
0040: Fmax
(1)
0080: TACC/TDEC mult.
(2)
00C0: VB mult. Factor
(3)
0020: CL mult. Factor
(4)