— 6 —
Alignment Point Location on Handset Main PCB
Power
Meter
RF
Test Point
HANDSET Unit
J601
Battery
Connector
1kHz 9mV
AF GEN.
DC 3.8V
Frequency
Counter
Deviation
Meter
RF
Test Point
MIC+Pin
DC Power Supply
Handset Unit
Transmitter Section
Connections
Alignment Procedure
step
1
2
3
Adjustment
RT601
(TX Power)
CT601
(TX Frequency)
RT602
(TX Modulation)
Remarks
Connect the RF power Meter to the RF test point on the handset MAIN PCB.
Adjust RT601 for a -5.0dBm reading on the Power Meter.
Connect the Frequency Counter to the RF test point on the handset MAIN
PCB. Adjust CT601 to make sure that the frequency is 903.052467 MHz.
Press the “2” key to enter the TEST Mode 2. Connect the AF Generator to
the MIC Connector. Make sure that the output is 1kHz 9mV from the AF
Generator.
Connect the Deviation Meter to the RF test point on the handset MAIN PCB.
Adjust RT602 to indicate
±
8 kHz Dev.
Preset
a) Connect DC power supply to battery connector on the handset unit.
b) Turn the DC power supply ON while pressing “
∗
” and “ # ” keys, and keep pressing the keys continuously for
approximate 2 seconds.
c) Release keys when entering TEST mode 1 with TALK LED lighting and beep.
HAND Main PCB
J601
RF Test Point
MC601
CT601
RT602
RT601
Summary of Contents for FT-8901A
Page 1: ...SERVICE MANUAL PUBLISHED IN JAPAN Oct 2001 FILE NO 2BO 200113 FT 8901A CORDLESS TELEPHONE ...
Page 9: ...BLOCK DIAGRAMS Base Unit 8 ...
Page 10: ... 9 Handset Unit ...
Page 12: ...Base Key Unit 12 13 FT8901A Sche p65 01 10 15 10 42 Page 9 Adobe PageMaker 6 5J Win ...
Page 26: ... 28 Unit V Ref No Pin STBY TALK Note Note 61 2 9 2 9 IC608 62 2 9 2 9 63 2 9 2 9 64 2 9 2 9 ...
Page 29: ... 31 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 30: ... 32 Base Unit Key PCB ...
Page 31: ... 33 Handset Unit Main PCB ...
Page 32: ... 34 WIRING DIAGRAMS Base Unit ...
Page 33: ... 35 Handset Unit ...