TROUBLESHOOTING HINTS
1. The bell of base unit does not ring.
When the PAGE SW of the
base is pressed, does the
ringer on the handset ring?
When the TEL SG is joined
with the base to make bell
signal, is there pulse wave at
Pin 4 of IC3?
Is there pulse wave at
Pin 79 of IC6?
Check IC6 and its
peripheral circuit.
Check IC3 and TEL network
circuit.
Check R76, R232 and R234.
See 2. The bell does not ring
& page does not ring.
OK
OK
NG
NG
OK
NG
Check RINGER mode setting
is Hi or Low.
Set RINGER volume setting
to Hi or Low.
OK
NG
If you want to reset the unit to the factroy settings
You can cancel the OGM, PIN, and the clock settings by the following process.
1 Disconnect the AC adaptor and telephone line cord from the base. Keep the AC adaptor connected to the wall
outlet. Make sure that the telephone line cord remains disconnected during this procedure.
2
A beep sounds and “ P” blinks in the LED display.
To resume using the unit, connect the telephone line cord and place the handset on the base.
Note:
If you turn on the unit again, “ P” may flash.
While pressing the DELETE button, plug the AC power adaptor into the base. Keep pressing the DELETE
button for more than 5 seconds.
Summary of Contents for FT-8901A
Page 1: ...SERVICE MANUAL PUBLISHED IN JAPAN Oct 2001 FILE NO 2BO 200113 FT 8901A CORDLESS TELEPHONE ...
Page 9: ...BLOCK DIAGRAMS Base Unit 8 ...
Page 10: ... 9 Handset Unit ...
Page 12: ...Base Key Unit 12 13 FT8901A Sche p65 01 10 15 10 42 Page 9 Adobe PageMaker 6 5J Win ...
Page 26: ... 28 Unit V Ref No Pin STBY TALK Note Note 61 2 9 2 9 IC608 62 2 9 2 9 63 2 9 2 9 64 2 9 2 9 ...
Page 29: ... 31 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 30: ... 32 Base Unit Key PCB ...
Page 31: ... 33 Handset Unit Main PCB ...
Page 32: ... 34 WIRING DIAGRAMS Base Unit ...
Page 33: ... 35 Handset Unit ...