4
Test Mode For Handset Unit
To perform the TEST mode, turn the power ON by pressing the “
*
” and “#” buttons at the same time.
When entered the TEST mode, the bell rings and the unit enters TEST mode 1. (Refer to the following table.)
1. To change the TEST mode: Press the number key for the corresponding TEST mode.
(Refer to the following table)
2. To change channel:
Press “CH” key.
(Note: If the step is changed, the channel returns to the start channel.)
3. To cancel the Test mode:
Turn the power OFF, charge the Handset, or press the “TALK” key.
STEP
FUNCTION
KE
START CH TX CONT
SC
TX MUTE RX MUTE CONV REMARKS
1
VO/TX FRQ. ADJ
1
21
L
H
L
L
H
2
TX MOD. CHECK
2
21
L
H
H
L
L
3
TX DATA
3
21
L
H
L
L
L
*1
4
RX SENS.
4
21
H
H
L
H
L
5
SQ SENS.
5
21
L
H
L
*A
L
6
RECEIVE DATA CHECK
6
21
L
H
L
L
H
*2
7
BELL
7
21
H
L
L
L
H
*3
8
BATTERY LOW CHECK
8
21
H
L
L
L
H
*4
9
CHARGE CHECK
9
21
H
L
L
L
H
*5
10
DUPLE
0
21
L
H
H
H
L
*A : Squelch ON is H, or Squelch OFF is L.
*1 : In the TEST mode 3, “0000...” will be fed out continuously as transmitting data.
*2 : In the TEST mode 6, bell (1kHz) rings when the data received is “0000...”.
*3 : In the TEST mode 7, bell rings with initial 2 tone (2kHz, 2.2kHz).
*4 : In the TEST mode 8, bell (1kHz) rings when P_BATLOW is “L”.
*5 : In the TEST mode 9, bell rings when P_CHRGIN is “L”.
Channel rotation
21
Ö
20
Ö
19
Ö
40
Ö
1
Ö
2
Ö
3
Ö
4
Ö
5............37
Ö
38
Ö
39
Ö
40
Summary of Contents for FT-8509
Page 2: ... 121 5 30 36 6 59 0 18 25 66 7 3 21 70 83 38 6 1 3 1 XJ1 4 ...
Page 11: ...9 BLOCK DIAGRAMS Base Unit ...
Page 12: ...10 Handset Unit ...
Page 13: ...6 0 7 5 06 DVH 8QLW 0DLQ 45 44 ...
Page 15: ... DQGVHW 0DLQ 48 47 ...
Page 30: ...30 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 31: ...31 Base Unit Key PCB ...
Page 32: ...32 Handset Main PCB ...
Page 33: ...33 WIRING DIAGRAMS Base Unit ...
Page 34: ...34 Handset ...
Page 37: ...37 7 8 4 1 16 17 17 5 10 15 11 12 2 9 6 13 14 3 17 Handset RF MODULE HANDSET MAIN PCB ASSY ...
Page 53: ......