3
ALIGNMENT PROCEDURE
Test Mode For Base Unit
Press the “
*
” and “#” keys at the same time about 1.5 seconds while turning the power on, the confirmation
beep will sound to indicate that the unit is in the test mode.
1. To change the TEST mode: Press the number key for the corresponding TEST mode.
(Refer to the following table)
2. To change channel:
Press the “RDL” key, but if changing the step, the channel returns to the start
channel.
3. To cancel Test mode:
Bell rings, charge the Handset or Power off.
STEP
FUNCTION
KE
START CH
TX CONT
TX MUTE
RX MUTE
RL CONT
REMARKS
1
VO/TX FRQ. ADJ
1
19
L
L
L
L
2
TX MODE CHECK
2
19
L
H
L
H
3
TX DATA
3
19
L
L
L
L
*1
4
RX SENS.
4
19
H
L
H
H
5
SQ SENS.
5
19
L
L
H/L
H
*2
6
RING CHECK
6
19
H
L
L
L
7
DUAL TONE CHECK
7
19
H
L
L
H
*3
8
DATA IN CHECK
8
19
L
L
L
H
*4
9
CHANNEL D ATA CHECK
9
19
H
L
L
L
*5
10
DUPLE
0
19
L
H
H
H
11
INT COM
MEM
19
L
H
H
L
*1 : “0000...” (250Hz) will be fed out continuously as transmitting data.
*2 : Bell rings when sensing SQ.
*3 : Every pushing of FLASH key makes tone change. (In the case of Dual Tone, changes as
1
Ö
2
Ö
3
Ö
4
Ö
5
Ö
6
Ö
7
Ö
8
Ö
9
Ö
0
Ö
∗
Ö
#
Ö
1.)
DTMF Frequency
ROW1 : 697
ROW2 : 770
ROW3 : 852
ROW4 : 941
COL1
: 1209
COL2
: 1336
COL3
: 1477
*4 : Bell rings when the received data are “0000...” (250Hz).
*5 : Charge LED lights when detecting Charge ON.
Channel rotation
19
Ö
20
Ö
21
Ö
40
Ö
1
Ö
2
Ö
3
Ö
4
Ö
5............37
Ö
38
Ö
39
Ö
40
Summary of Contents for FT-8509
Page 2: ... 121 5 30 36 6 59 0 18 25 66 7 3 21 70 83 38 6 1 3 1 XJ1 4 ...
Page 11: ...9 BLOCK DIAGRAMS Base Unit ...
Page 12: ...10 Handset Unit ...
Page 13: ...6 0 7 5 06 DVH 8QLW 0DLQ 45 44 ...
Page 15: ... DQGVHW 0DLQ 48 47 ...
Page 30: ...30 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 31: ...31 Base Unit Key PCB ...
Page 32: ...32 Handset Main PCB ...
Page 33: ...33 WIRING DIAGRAMS Base Unit ...
Page 34: ...34 Handset ...
Page 37: ...37 7 8 4 1 16 17 17 5 10 15 11 12 2 9 6 13 14 3 17 Handset RF MODULE HANDSET MAIN PCB ASSY ...
Page 53: ......