© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 12
6.6
Disassembly and Replacement
[A] Original glass
(1)
Remove 2 rubber caps and 2 screws, take off
the original glass holder while sliding it to the
right.
Fig. 6-7
(2)
Remove 2 rubber caps and 2 screws, take off
the original glass.
Notes:
1. When handling the original glass, take
care not to contaminate the surface with
fingerprints or such.
2. Do not place the original glass directly on
the floor.
3. When installing the original glass, fit 2
guides of the original glass in the groove
of the scanner top cover.
Fig. 6-8
(3)
Take off the ADF original glass.
Fig. 6-9
Original glass holder
Rubber cap
Original glass
Rubber cap
ADF Original glass
07/02
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 66: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 14 ...
Page 86: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved CONTROL PANEL 5 8 ...
Page 120: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved LASER OPTICAL UNIT 8 8 ...
Page 130: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved DRIVE UNIT 9 10 ...
Page 222: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved FUSER EXIT UNIT 13 20 ...
Page 230: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 14 8 ...
Page 234: ...e STUDIO163 203 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PC BOARDS 15 4 ...
Page 235: ......
Page 236: ......