e-STUDIO160/200/250 ADJUSTMENT ITEMS
1 - 40
December 2002 TOSHIBA TEC
Service parameter setting
RAM clear table
RAM data
RAM clear mode
[1] [3] [*] and turn ON *2) *3)
[1] [3] [#] and turn ON
*2)
[*] [#] and turn ON
*2)
[START] [STOP] and
turn ON
*2)
[0] [8] and turn ON, then
[6] [6] [5]
*1)
[0] [2] and turn ON
1. PIX MEMORY
2. EXCEPT USER MEMORY
3. ALL
*3)
(Same as “[1] [3] [*] and turn ON”)
4. USER AREA
*3)
Country/
Region
setting
Changeable
FUNC/
SYSFUNC/
UAD etc.
Set default
value
Set default
value
Set default
value
Set default
value
Set default
value
Service
adjustment
data ([0][5])
area
Set default
value
Service
setting data
([0][8]) area
Set default
value *e)
Set default
value *e)
Set default
value
Set default
value *e)
Set default
value *e)
Journal
report
data
Clear
Clear
Clear
Clear
Clear
Error data
on FAX
communi-
cation
Clear
Clear
Clear
Clear
Clear
Protocol
trace
data
Clear
Clear
Clear
Clear
Clear
Clear
Clear
Clear
Drum
related
data
*b)
Counter
data
*a)
Clear
*1) In case of replacing the main board in the field, you can initializes the parameters
related to copy function stored on the board using this function.
Therefore when this function is performed, it is necessary to readjust the follow-
ing items.
1) Adjustment of paper aligning value
2) Printer unit adjustment
3) Scanner unit adjustment
4) ADF/RADF installation setting
*2) When RAM clear is performed, no message is indicated on the LCD.
Once RAM clear has been completed, “Please wait” appears on the LCD.
*3) RAM clear may take more than 10 seconds. Note that the error (Broken Regis-
tration) results if the power is turned off during RAM clear.